26
Assembly and connection
Assembly Instructions
Linear Tables HT-L
HTL-01-0-EN-1905-MA
Fig. 6.4
Horizontal axis position
Fig. 6.5
Vertical axis position
6.1.1 Maximum support spacing for linear tables HT-L in self-supporting applications
Depending on how the linear axis is fixed, the axis body may undergo excessive bending, especially with large stroke lengths
and high load capacities. This can be prevented when the axis body is mounted on multiple supports on a stable sub
construction. The maximum support spacing L is a function of the acting force and can be determined from the following
diagrams. In the case of multi-axis systems, the masses of the moving axes must also be taken into account.
F
z
F
z
F
y
L
L
F
y
L
L
0
500
1,000
1,500
2,000
2,500
3,000
500
1,500
2,000
1,000
2,500
3,000
HT250
HT200
HT150
Max. support spacing L [mm]
Force
F
z
[N]
Fig. 6.6
Maximum support spacing as a function of the force F
z
0
500
1,000
1,500
2,000
2,500
3,000
500
1,500 2,000
1,000
2,500
5,000
3,000 3,500
4,500
4,000
HT250
HT200
HT150
Max. support spacing L [mm]
Force
F
y
[N]
Fig. 6.7
Maximum support spacing as a function of the force F
y
Содержание 25.12345
Страница 1: ...Assembly Instructions Linear Tables HT L www hiwin de Valid from serial no HSN0000000001...
Страница 61: ...61 Assembly Instructions Linear Tables HT L HTL 01 0 EN 1905 MA Notes...
Страница 62: ...62 Assembly Instructions Linear Tables HT L HTL 01 0 EN 1905 MA Notes...
Страница 63: ...Appendix 2 Declaration of Incorporation 63 Assembly Instructions Linear Tables HT L HTL 01 0 EN 1905 MA...