Model 

Flue Size (Sq. Inch) 

Minimum (Sq. inch) 

Maximum (Sq. Inch) Int/Ext 

Stoker 

 

6” 

28 sq. in. 

6” 

28 sq. in. 

 

84 sq. in.  

          interior 

Furnace 

 

6” 

28 sq. in. 

6” 

28 sq. in. 

 

56 sq. in. 

         exterior 

 

Chimney Height Requirements: 

The minimum height of a chimney system for the Hitzer Stove is 15 

feet.  The chimney must exceed the roof of a house a minimum of 3 feet at any point of exit.  In pitched 
roof installation the chimney must be at least 2 feet higher than anything within a 10 foot radius of the 
chimney.  It is important to have a chimney draft of .03 - .06 wc. Never operate your furnace at a flue draft 
exceeding .06 wc (14.945 Pa) or less than .03wc (7.473 Pa)

. It is required to abide by the manufacture’s 

instructions on class A chimney’s as well as local building codes.  
 
All of these requirements must be followed to ensure the best chances for good draft. There are however 
many environmental factors that can effect your draft. A few of these include wind speed and direction, 
obstructions diverting winds, barometric pressure and humidity. This is why it is essential to have a 
barometric damper and carbon monoxide detectors/alarms installed and working properly.     

 

 

 

 

 

Power Vent System: 

A  Hitzer approved power vent may be used in place of a chimney.  BE SURE TO READ YOUR POWER 
VENTER INSTALLATION AND OPERATION INSTRUCTION MANUAL BEFORE USING THE POWER 
VENTER. Follow the instructions that come with the power venter, for cutting the hole, and mounting the 
venter to the wall. Connect your Hitzer Energy Master II Stoker Furnace to the power vent using a 6 inch 
stove pipe and a barometric damper. You need to make certain that the pipe joints are tight together and 
screwed with a minimum of three sheet metal screws per joint. 

Once you have the vent system 

installed you can then install the wall control thermostat system according to the COAL-TROL 
DIGITAL™   instruction manual which is supplied in the thermostat box. 

 

Note:  

-Illustrations are not drawn to 
scale 
-For design purposes only 
-Actual Installations may vary 

Содержание Energy Master II 710

Страница 1: ...SONAL INJURY OR EVEN DEATH REFER TO MARKINGS ON THE FURNACE FOR ADDITIONAL INFORMATION CARBON MONOXIDE AND SMOKE DETECTORS ALARMS MUST BE INSTALLED IN THE HOME AND WORKING PROPERLY DANGER RISK OF FIRE OR EXPLOSION DO NOT BURN GARBAGE GASOLINE DRAIN OIL OR OTHER FLAMMABLE LIQUIDS DO NOT USE CHEMICALS OR FLUIDS TO START FIRE BURN RICE SIZE ANTHRACITE COAL ONLY STOVE SURFACES MAY BE HOT WHILE IN OPER...

Страница 2: ...eturn Air D Combustion Air E Installation In A Confined Space IV Flue Systems A Masonry System B Factory Built Systems C Chimney Requirements D Flue Size E Chimney Height Requirements F Power Vent System V Basic Regulations for Safe Operations A Cautions B Local Codes VI Stove Start Up Operation A Install Coal Trol Thermostat B Start Up C Adjusting Chimney Draft D Measuring Furnace Compatibility V...

Страница 3: ...fire follow the installation instructions carefully Failure to follow these instructions may result in property damage bodily injury or even death Contact your local building inspector or fire officials about the need for a permit restrictions or installation inspection required in your area Refer to makings on your furnace for more information Save these instructions for future reference Safety N...

Страница 4: ... Once it is determined your existing furnace will accept an add on installation a parallel installation with return air outlined later in this manual is recommended 3 Can the furnace be vented properly a Is the chimney appropriate for this installation This furnace requires installation in a masonry chimney with a clay flue liner or a metal all fuel chimney listed to UL103 CAN ULC S629 M87 Type HT...

Страница 5: ...ated and make placement of the Energy Master Furnace to achieve maximum heat benefit it can produce Clearances To Combustibles Floor Protection This furnace must be placed on a non combustible floor If the floor is a combustible material floor protection must be placed underneath it and extend at least 8 inches on each side of the fuel or ash door It must also extend 16 inches out from the front o...

Страница 6: ...ter Furnace to the chimney should be made as direct as possible It is not recommended to use more then 2 elbows for venting The pipe connecting the furnace to the chimney should be at least 24 gauge single wall pipe Thicker gauges and double wall pipe may be used A inch slope back toward the furnace per foot of horizontal run is required This allows any condensation forming in the pipe to flow bac...

Страница 7: ...Page 7 ...

Страница 8: ...are drawn with a masonry chimney Manufactured metal chimney listed to UL 103 CAN ULC S629 M87 Type HT or a Hitzer approved power vent system may also be used Follow manufacturer s instructions guidelines when using these products ...

Страница 9: ...our basement unnecessarily heating unused portions of your home The return duct should be a minimum of 16 x 20 or equivalent 320sq in The return duct may be attached to the rear of the stoker furnace Make sure if you are attaching the duct to the rear of the furnace you do not inhibit the removal and replacement of the furnace filters These filters should be checked and cleaned replaced regularly ...

Страница 10: ... Supplemental add on Furnace Installations Do not use duct elbows having an inside radius of less than 6in 150mm on the oil gas electric furnace Do not connect to a down flow furnace Do not connect ductwork so that a reverse flow is possible Operate the gas oil electric furnace periodically to ensure it will operate satisfactorily when needed Certified for installation with the ductwork configurat...

Страница 11: ... only have one appliance per chimney and it is not permissible to connect your Hitzer Energy Master II furnace to a chimney that is servicing another appliance Flue Requirements It is required to have a chimney that is built according to the chimney manufacturer s specifications and meets local building codes It is also required to have your chimney inspected and cleaned by a certified chimney pro...

Страница 12: ...our draft A few of these include wind speed and direction obstructions diverting winds barometric pressure and humidity This is why it is essential to have a barometric damper and carbon monoxide detectors alarms installed and working properly Power Vent System A Hitzer approved power vent may be used in place of a chimney BE SURE TO READ YOUR POWER VENTER INSTALLATION AND OPERATION INSTRUCTION MA...

Страница 13: ...he properly constructed and in good top of the fire box When the door is condition Chimney must be at least 15 opened oxygen combines with gases high and exceed the roof a minimum of and ignites 3 feet unless using Power Vent System WARNING Risk of Fire WARNING Over Fire Unit Comply with all minimum clearances to Do NOT over fire your unit combustibles as specified This will cause warping of fire ...

Страница 14: ... hole to read the chimney draft Adjust the barometric damper so that your manometer reads between 03 and 06 inches of water column following the instructions provided with the damper Do not run at a draft above 06 inches of water column as this could cause your stoker to over fire Over firing can cause a dangerous fire hazard It would be best to set it with a manometer if available The settings on...

Страница 15: ...amount of coal burned ash content of the coal the burn rate and draft of the chimney Allow stoker to run out of coal go out and cool down Remove chimney connector pipes and check and remove any fly ash accumulation This will mainly be at the bottom of elbows and horizontal runs Remove all fly ash from heat exchanger plates inside and below the flue collar and on the floor of the stoker around the ...

Страница 16: ...Page 16 VI Troubleshooting ...

Страница 17: ...rmined by the capacity and condition of the battery and the amount of heat needed Some generators will also work however the output of either must be a pure sine wave Other outputs can cause the Coal Troll Digital to not work You may also contact your Hitzer dealer or Hitzer Inc for questions or more information regarding stove installation and operation Hitzer Inc 269 E Main St Berne IN 46711 260...

Отзывы: