Page 4
II. Location of Stove & Installation
Pre Installation Information:
Your Energy Master Furnace is intended for use in residential buildings. Do not install in a mobile home.
Do not install in a garage.
IMPORTANT: Always check with local authorities and obtain the necessary permits prior to
installing this furnace. This furnace must be installed in accordance with local, state, and national
codes and regulations.
Before installation some questions must be addressed.
1. Will your Energy Master Furnace be used as a primary (central) furnace, or will it be installed as an
add-on to your existing central heating system?
2. If your Energy Master Furnace is to be installed as an add-on, is it compatible with your existing
furnace? Your Energy Master Furnace is designed to be used with a listed gas-, oil-fired furnace
however not all furnaces will accept add-on applications. Some small furnaces, and especially counter-
flow or down-flow furnaces, can not be used in an add-on installation. The CFM (cubic feet per minute)
capability between the blower on the existing furnace and the add-on furnace must be compatible. If all
these conditions are met then the combined static pressure must not exceed the maximum static
pressure listed on the nameplate on either furnace. Before installing your Energy Master Furnace consult
your Hitzer dealer or heating contractor and your local, state and national building codes and regulations
to determine if your central heating system is compatible with your Hitzer Energy Master Furnace. Once it
is determined your existing furnace will accept an add-on installation a parallel installation with return air
(outlined later in this manual) is recommended.
3. Can the furnace be vented properly?
a. Is the chimney appropriate for this installation? This furnace requires installation in a masonry
chimney with a clay flue liner or a metal all-fuel chimney listed to UL103 (CAN/ULC-S629-M87) Type HT.
Do not connect this furnace to a chimney serving another appliance!
b. Has your chimney been inspected? It is important that your chimney is clean and structurally sound
(free from defect or damage) before installing your Energy Master Furnace.
c. If you are power venting your furnace is there a place to mount the power vent away from
obstacles? Refer to power vent placement chart with power vent instructions.
4. Is there easy access to outside combustion air should your furnace require it?
5. Can the furnace be installed safely?
a. This furnace must not be installed in a location where it could come in contact with walls, carpeting,
curtains/drapes, or other combustible surfaces.
b. The clearances listed in this manual and on the furnace are minimum clearances. Any reduction
must be approved by the regulatory authority and is not recommended by Hitzer Inc.
c. Will this location require floor protection?
d. Furnace must not be installed in a sleeping room.
6. How close is the electrical source and does it conform to requirements listed?
7. Are there any local, state, or national codes or regulations concerning the use and placement of your
furnace?
8. Are there any structural reasons why the furnace cannot be located where you want it?
9. Will the furnace be easily accessible for refueling, cleaning, maintenance, and repair?