7-52
MAINTENANCE
Table 1. Hoses
Interval (hours)
Check Points
Abnormalities
Remedies
Daily
Hose covers
Leak (1)
Replace
Hose ends
Leak (2)
Replace
Fittings
Leak (3)
Retighten or replace
hose or O-ring
Every 250
hours
Hose covers
Crack (4)
Replace
Hose ends
Crack (5)
Replace
Hose covers
Exposed reinforcement
(6)
Replace
Hose covers
Blister (7)
Replace
Hose
Bend (8)
Replace (Use proper
bend radius)
Hose
Collapse (9)
Replace (Use proper
bend radius)
Hose ends and
fittings
Deformation or
Corrosion (10)
Replace
f
NOTE: Refer to the illustrations in Fig. 1 for each check point location or for a description of
the abnormality. Use genuine Hitachi parts.
M137-07-008
M115-07-145
M115-07-146
M115-07-147
M115-07-148
M115-07-149
9
10
8
6
7
4
5
3
2
1
2
3
3
2
1
2
3
Fig. 1
Содержание ZW 370-6
Страница 4: ...MEMO ...
Страница 10: ...CONTENTS MEMO ...
Страница 12: ...2 MACHINE NUMBERS Aftertreatment Device SCR TYPE MFG NO DOC TYPE MFG NO 95Z7B SCR4 95Z7B SCR4 ...
Страница 53: ...SAFETY LABELS S 41 95Z7B S 40 ...
Страница 148: ...1 84 OPERATOR S STATION MEMO ...
Страница 218: ...OPERATOR S STATION 1 154 MEMO ...
Страница 220: ...2 2 BREAK IN MEMO ...
Страница 236: ...3 16 OPERATING THE ENGINE MEMO ...
Страница 284: ...OPERATING THE MACHINE 5 28 MEMO ...
Страница 426: ...MAINTENANCE 7 132 MEMO ...
Страница 430: ...9 4 MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS MEMO ...
Страница 434: ...10 4 STORAGE MEMO ...
Страница 440: ...11 6 TROUBLESHOOTING MEMO ...
Страница 442: ...12 2 SPECIFICATIONS MEMO ...
Страница 450: ...14 8 INDEX MEMO ...