1. Reset Circuit
●
The reset circuit is used to reset the program to its initial settings when the power is turned on or when the
power is recovered after a power failure.
●
The micro computer is reset when the reset input is “Hi”, and operation is possible when the reset input is
“Lo”.
●
The waveforms at each point when the power is turned on and off are shown in the diagrams.
●
When the power is turned on, the voltages of the DC 12V line and DC 5V lines are increased. When the
voltage of DC 12V lines reaches about 7V, ZD202 is turned ON, the potential of Q201’s base rises and Q202
is turned ON. Since Q202’s collector is set to “LO” at this time, Q202 is turned OFF and the reset input of
the micro computer is set to “Lo”. The DC 5V line voltage has already become 5V at this time and the micro
computer starts operation.
●
When the power is turned OFF, the voltage of the DC 12V line decreases. When it becomes about 7V, ZD202
is turned OFF, then Q201 is turned OFF, Q202 is turned ON the reset input of the micro computer is set to
“Hi’ and the micro computer is set to the reset mode.
POWER ON
12V
7V
5V
DC12V Line
DC5V Line
Base
POWER OFF
5V
Micro computer
Pin 7
12V
5V
0V
0V
Q201
C202
7
Micro computer
RES
Q202
ZD202
R205
R201
R204
R202
R203
+
C201
DESCRIPTION OF MAIN CIRCUIT OPERATION
0305E Pg 57-82
4/1/06, 10:59 AM
59
Содержание Summit RAC-70YH5
Страница 34: ... 32 INDOOR UNIT OUTDOOR UNIT WIRING DIAGRAM MODEL RAS 70YH5 RAC 70YH5 0305E Pg 28 32 4 1 06 10 50 AM 32 ...
Страница 36: ... 35 CIRCUIT DIAGRAM MODEL RAS 70YH5 0305E Pg 35 4 1 06 10 52 AM 1 ...
Страница 37: ... 37 CIRCUIT DIAGRAM MODEL RAC 70YH5 0305E Pg 37 4 1 06 10 53 AM 1 ...
Страница 39: ... 40 MODEL RAC 70YH5 MAIN P W B 0305E Pg 39 42 4 1 06 10 53 AM 40 ...
Страница 40: ... 41 MAIN P W B NF P W B CAPA P W B 0305E Pg 39 42 4 1 06 10 53 AM 41 ...
Страница 42: ... 43 51 53 53 55 57 49 29 66 22 0305E Pg 43 4 1 06 10 54 AM 1 ...
Страница 86: ... 94 6 Check the main P W B power circuit 0305E Pg 90 109 4 1 06 11 01 AM 94 ...
Страница 87: ... 95 CHECKING THE REMOTE CONTROLLER 0305E Pg 90 109 4 1 06 11 01 AM 95 ...
Страница 92: ... 100 0305E Pg 90 109 4 1 06 11 01 AM 100 ...
Страница 102: ...HITACHI PM NO 0305E Printed in Malaysia RAS 70YH5 RAC 70YH5 0305E cover 4 1 06 12 03 PM 2 ...