– 77 –
9. Reset Circuit
●
Reset circuit performs initial setting of the microcomputer program when power is turned on.
●
Microcomputer resets program with reset voltage set to Lo, to enable operation at Hi level.
●
Fig. 9-1 shows the reset circuit, and Fig. 9-2 shows waveform at each point when power is turned on/
off.
●
After power is turned on, 12V line and 5V line voltages rise: When 12V line voltage reaches 7.2V (Zener
voltage of ZD201), ZD201 turns ON and Q211 and Q205 turn on, and reset voltage becomes Hi. Reset
voltage is not set to Hi until VDD of microcomputer rises to 5V, enabling operation, due to ZD201.
●
After power turns off, when 12V line voltage drops, ZD201 also turns OFF.
12V line
12V line
5V line
5V line
Reset voltage
Reset voltage
12
6
0
V
oltage when power is turned ON
12
6
0
V
oltage when power is turned OFF
Time
Time
Fig. 9-1
0V
0V
0V
C224
5V
Q212
C223
R368
R369
R367
R365
C351
R366
Q205
R345
48
12V
ZD201
Reset
(AX-6S00)
Outdoor
Microcomputer
Fig. 9-2
0305E Pg 57-82
4/1/06, 10:59 AM
77
Содержание Summit RAC-70YH5
Страница 34: ... 32 INDOOR UNIT OUTDOOR UNIT WIRING DIAGRAM MODEL RAS 70YH5 RAC 70YH5 0305E Pg 28 32 4 1 06 10 50 AM 32 ...
Страница 36: ... 35 CIRCUIT DIAGRAM MODEL RAS 70YH5 0305E Pg 35 4 1 06 10 52 AM 1 ...
Страница 37: ... 37 CIRCUIT DIAGRAM MODEL RAC 70YH5 0305E Pg 37 4 1 06 10 53 AM 1 ...
Страница 39: ... 40 MODEL RAC 70YH5 MAIN P W B 0305E Pg 39 42 4 1 06 10 53 AM 40 ...
Страница 40: ... 41 MAIN P W B NF P W B CAPA P W B 0305E Pg 39 42 4 1 06 10 53 AM 41 ...
Страница 42: ... 43 51 53 53 55 57 49 29 66 22 0305E Pg 43 4 1 06 10 54 AM 1 ...
Страница 86: ... 94 6 Check the main P W B power circuit 0305E Pg 90 109 4 1 06 11 01 AM 94 ...
Страница 87: ... 95 CHECKING THE REMOTE CONTROLLER 0305E Pg 90 109 4 1 06 11 01 AM 95 ...
Страница 92: ... 100 0305E Pg 90 109 4 1 06 11 01 AM 100 ...
Страница 102: ...HITACHI PM NO 0305E Printed in Malaysia RAS 70YH5 RAC 70YH5 0305E cover 4 1 06 12 03 PM 2 ...