Chapter 10 LCD display and operating for SJ300/L300P series
201
Input FW a/b
(NO/NC) selection
>C019 IN-TM
O/C-FW NO
NO
:
NO
NC
:
NC
202
Intelligent output
11 setting
>C021 OUT-TM
11 FA1
203
Intelligent output
12 setting
>C022 OUT-TM
12 RUN
204
Intelligent output
13 setting (NOTE 1)
>C023 OUT-TM
13 OL
205
Intelligent output
14 setting (NOTE 1)
>C024 OUT-TM
14 OTQ
206
Intelligent output
15 setting (NOTE 1)
>C025 OUT-TM
15 IP
207 Alarm
relay
output
>C026 OUT-TM
AL AL
RUN(running) / FA1(Frequency arrival type1
signal) / FA2(over setting frequency) /
OL(Overload advance notice signal) /
OD(Output deviation for PID control) /
AL(Alarm signal) / FA3(Only setting
frequency) / OTQ(Over-torque signal) / IP(On
instantaneous stop) / UV(Under voltage) /
TRQ(Torque limit) / RNT(RUN time over) /
ONT(ON time over) / THM(thermal caution) /
BRK(Brake release signal) / BER(Brake error
signal) / ZS(Zero speed detect signal) /
DSE(Speed error over signal) /
POK(Positioning completion signal) /
FA4(Over frequency 2 signal) / FA5(Only
setting frequency) / OL2(Overload advance
notice signal 2) (Intelligent output terminal
11-13 or 11-14 becomes AC0-AC2 or
AC0-AC3 (Can; Alarm cord output) forcibly
when alarm code output is selected in C062)
(NOTE 2)
208 FM
selection
>C027
FM-MONITOR
KIND A-F
A-F(Output frequency) / A(Output current) /
T(Output torque) / D-F(Digital output
frequency) / V(Output voltage) / P(Input
electric power) / THM(:thermal load rate) /
LAD(LAD frequency) (NOTE 3)
209 AM
selection
>C028
AM-MONITOR
KIND A-F
A-F(Output frequency) / A(Output current) /
T(Output torque) / V(Output voltage) / P(Input
electric power)/ THM(thermal load rate) /
LAD(LAD frequency) (NOTE 3)
210 AM
selection
>C029 AMI-MON
KIND A-F
A-F(Output frequency) / A(Output current) /
T(Output torque) / V(Output voltage) / P(Input
electric power)/ THM(thermal load rate) /
LAD(LAD frequency) (NOTE 3)
211
Intelligent output 11
a/b
>C031 OUT-TM
O/C-11 NO
NO
:
NO
NC
:
NC
212
Intelligent output 12
a/b
>C032 OUT-TM
O/C-12 NO
NO
:
NO
NC
:
NC
213
Intelligent output 13
a/b
>C033 OUT-TM
O/C-13 NO
NO
:
NO
NC
:
NC (NOTE 1)
214
Intelligent output 14
a/b
>C034 OUT-TM
O/C-14 NO
NO
:
NO
NC
:
NC (NOTE 1)
215
Intelligent output 15
a/b
>C035 OUT-TM
O/C-15 NO
NO
:
NO
NC
:
NC (NOTE 1)
(NOTE 1) SJ300 series only .
(NOTE 2) L300P series : RUN / FA1 / FA2 / OL / OD / AL / FA3 / IP / UV / RNT / ONT / THM
(NOTE 3) L300P series : Except T (Output Torque )