Chapter 10 LCD display and operating for SJ300/L300P series
129
Overload restriction
level 2
>b025 OLOAD
2LEVEL 0000.0A
0.5* rated current-2.00* rated current(A)
(NOTE 2)
130
Overload restriction
limit constant 2
>b026 OLOAD
2CONST 01.00
0.10 - 30.00(s)
131
Software lock mode
selection
>b031 S-LOCK
Mode MD1
MD0(impossible to change the data except
this item when SFT terminal is ON) /
MD1(impossible to change the data except
setting frequency item when SFT terminal is
ON) /
MD2(impossible to change the data except
this item) /
MD3(impossible to change the data except
setting frequency item) / MD10(possible to
change data on operating)
132
RUN time/Power
ON
time level
>b034 TIME
WARN 00000
0 – 65535 (
×
10hr)
133
Operation direction
restrict
>b035 LIMIT
F/R FREE
FREE(forward and reverse are valid) /
FWD(only forward) / REV(only reverse)
134
start reduced
voltage
>b036 RVS
ADJUST 06
00(start reduce voltage time small)
-06(start reduced voltage time large)
135 Display
selection
>b037 DISP
Mode ALL
ALL(all display) / FUNCTION(each function
display) / USER(user setting / main setting)
(NOTE 1) SJ300 series only .
(NOTE 2) L300P series : 0.5* rated current-1.50* rated current(A)
(7/15)
No.
Function name
Display
Data range
136
Torque limit mode
selection
>b040 TRQ_LIMIT
Mode 4-SET
4-SET(4 quadrant mode) / TM(terminal
operation) / O2 (Analog input) / OP1(Option 1)
/ OP2(option 2) (NOTE 1)
137
Torque limit level 1
setting
(Forward-regenerati
ng at 4
quadrant mode
>b041 TRQ_LIMIT
LEVEL1 150%
0 - 200(%),no( invalid)
(NOTE 1)
138
Torque limit level 2
(Reverse-regenerati
ng at 4
quadrant mode)
>b042 TRQ_LIMIT
LEVEL2 150%
0 - 200(%),no( invalid)
(NOTE 1)
139
Torque limit level 3
(Reverse-driving at
4
quadrant mode)
>b043 TRQ_LIMIT
LEVEL3 150%
0 - 200(%),no( invalid)
(NOTE 1)
140
Torque limit level 4
setting
(Forward-regenerati
ng at 4
quadrant mode
>b044 TRQ_LIMIT
LEVEL4 150%
0 - 200(%),no( invalid)
(NOTE 1)
141
Torque LAD-STOP
selection
>b045 TRQ_LIMIT
SELECT OFF
OFF(invalid) / ON(valid)
(NOTE 1)
142
Reverse run preven-
tion selection
>b046 LIMIT
PREV OFF
OFF(invalid) / ON(valid)
(NOTE 1)
143
Selection of
non-stop
function at instanta-
neous power failure
>b050 IPS-DECEL
Mode OFF
OFF(invalid) / ON(valid)
(NOTE 1)