Chapter 6 Setting operating mode
To change operating mode of the remote operator is written below. The setting data are validity after
Power ON again .
Inverter Type
BPS
OPERATOR TYPE
remarks
SJ300, L300P series
4800 SRW
SJ100 ,L100,J100,
L50 series
4800 DRW2
It is possible to monitor and data setting
,when “OPERATOR TYPE” is “DOP/DRW”.
But Copy function is restricted.(NOTE
3
)
J300,L300,J500,
JH300 series
4800 HRW
It is possible to monitor and data setting
,when “OPERATOR TYPE” is “DOP/DRW”,
”DRW2”. But Copy function is restricted .
(NOTE
3
)
LOCAL MODE
BPS
2400
2
STR
Press the key at the same time, in order to turn on power.
During press the key.,
"LOCAL MODE " will appear
CONFIGURATION
DIAGNOSE
Keep off the key,
"CONFIGURATION DIAGNOSE" will appear.
Press the key, when the cursor is the head of
REMT
FUN
―
REMT
FUN
―
REMT
FUN
―
SET DEFAULT
CANCEL
LANGUAGE SELECT
OFF
OPERATOR TYPE
SRW
3
3
2
3
3
2
3
3
3
3
2
2400
4800
9600
19200
CANCEL
EXECUTE
ON
OFF
DOP/DRW
DRW
HRW
SRW
REMT
STR
If press the key, data will be stored.
If press the key, back to the general operation.
Both the keys are used for changing the top and bottom row.
1
0
Comunicatin
g
speed(bps)
Whether set de-
fault or not
Language selection
top row.
Operator Type
(NOTE 2)
(NOTE 1)
(NOTE 2)
It is not possible to select “ON” in
SRW-0J
< SRW-0EX only >
(NOTE 1)
Select “EXECUTE “ ,and initialized ;
SRW-0J:
BPS : 4800
LANGUAGE SELECT : OFF
OPERATOR TYPE :SRW
SRW-0EX:
BPS : 4800
LANGUAGE SELECT : ON
OPERATOR TYPE :SRW
(
NOTE
3)
Refer to the each inverter instruction manual .