. CHECKING COMPONENTS
Test system flow
Cooling mode
Test system pressure.
Is
the low pressure
normal at service
part ?
The pressure on the
high side.
The pressure on the
low side.
Recharge refrigerant
after air purging with
the vacuum
pump.
Is
the low
pressure no
r
mal
over again?
Air remain
s
at the
refrigerant system.
yes
The system
need
s
refrigerant.The
service people must
add
refrigeran
t
.
Doe
s
the low pressure
rise ?
NO
Recharge
refrigerant .
yes
The refrigerant system
is
blocked.
Please check
the Capillary Tube
(
or
electronic
expansion valve)
Is
it blocked?
Unsolder the capillary tube
ASS'Y(or electronic expansion
valve).The capillary tube1 is blown
by N
2
.
Check check valve and 4-
way valve.
If the pressure is
close to static
pressure?
NO
NO
4-way valve collude or
compressor exhaust very
ebb.
yes
NO
yes
Heating mode
Test system
pressure.
Is
the high
pressure normal at
service part ?
The pressure on the
high side.
The pressure on the
low side.
Recharge refrigerant
after air purging with
the vacuum
pump.
Is
the high
pressure normal over
again?
Air remain
s
at the
refrigerant system.
yes
The system
need
s
refrigerant.
The service
people must
add
refrigerant
.
Doe
s the
high pressure rise in
heating mode?
NO
Recharge refrigerant
yes
If the pressure is close
to static pressure?
4-way valve collude or
compressor exhaust every
ebb.
yes
Check heat exchanger and
4-way valve.
NO
The capillary tube
is
blocked.Unsolder the
capillary tube ASS'Y.
The
capillary tube1 and
capillary tube2 is blown by
N
2
.
NO
Remove the back
panel."see"the
capillary tube1 and
capillary tube2.Is it
defrosting?
yes
NO
31