2
.TROUBLESHOOTING
Outdoor
u
nit
3.0/3.5HP
DC-Inverter unitary (Main
control
board
upside-down)
Fault code display
ed
by LED lamps on outdoor main control board.
There are 3 LED lamps on control board, LED1,
LED2 and LED3.
LED1 indicate
s
fault code
represented by 2-
digit number, LED2 indicate
s
fault code
represented
by
single digit number and LED3
indicate
s
outdoor drive control fault.
When LED3 is off, LED1 and LED 2 indicate main control fa
ult
code.
When LED3 is on, LED1 and LED 2 indicate drive control fa
ult
code.
When LED3 is flickering and LED1,
LED 2 are all off, indicate compressor is preheating.
Failures
display with 5s interval. It means LED will
be
off
for
5s to report next fa
ult
code.
System protect
ion
codes display method is the same with main control fa
ult
code.
LED lamps will
be
off when there is no failure, protect
ion
or preheating.
For example, outdoor main control fault 32:
For example, outdoor drive fault 32:
18