.TROUBLESHOOTING
Fault
code
Fault
d
escription
Possible
r
eason
s
for
a
bnormality
How to
d
eal
w
ith
R
emarks
12
V
oltage absent phase
Three-phase power is abnormal;
The outdoor wiring
is
connect
ed
improperly
;
The outdoor control board
fails
.
1.
Normal protection
;
2.
Check the wiring connection
refer
ring
to the wiring diagram;
3. Replace the outdoor control
board
.
Application of
three-phase
power supply
models
13 Compressor overheat
protector device
1.
The wiring of the overload
protector
is
connect
ed
loose
ly
;
2.
The overload protector fail
s
;
3.
The refrigerant is not enough;
4.
The installation pipe is
much
long
er
than
the
normal
one
, but
extra refrigerant
is not
add
ed
;
5.
The expansion valve
fails
;
6.
The outdoor control board
fails.
1. Reconnect the wiring of the
overload protector;
2. Replace the overload
protector;
3. Check the welding point of the
unit to confirm whether it is
leakage, and then recharge
the refrigerant;
4. Add the refrigerant;
5. Replace expansion valve;
6. Replace the outdoor control
board.
14
T
he high pressure
switch operat
ion
or
the unit
is
turn
ed
off
for high pressure
protection
1.
2.
The wiring of the high pressure
protector
is
connect
ed
loose
ly
;
The high pressure protector
fails;
3.The outdoor control board is
abnormal;
4. Overload in cooling;
5. Overload in heating.
1.
2.
Reconnect the wiring
of
the
high
pressure protector;
Replace the high pressure
protector;
3. Replace the outdoor control
board;
4. Please refer to
NOTE
3;
5. Please refer to N
OTE
4.
Applied to
models with
high
pressure
switch or
pressure
sensor
15
T
he low pressure
switch protection or
the unit
is
turn
ed
off
for low pressure
protection
1.
The wiring of the low pressure
switch
is
connect
ed
loose
ly
;
2.
The low pressure switch fail
s
;
3.
The refrigerant is not enough;
4.
The expansion valve fail
s
in
heating mode;
5.
The outdoor control board is
abnormal.
1.
Reconnect the wiring of the
low pressure switch;
2.
Replace the low pressure
switch;
3.
Check the welding point to
confirm whether the unit
leaks
,
and then
add some refrigerant;
4.
Replace the expansion valve;
5.
Replace the outdoor control
board.
Applied to
models with
low pressure
switch or
pressure
sensor
16
O
verload protection
in cooling mode
System overload
Please refer to
NOTE
3.
17
Discharge
temperature sensor
fault
1.
The wiring of the discharge
tempe
-
r
ature sensor
is
connect
ed
loose
ly
;
3.
The sampling circuit is abnormal.
1.Reconnect the wiring of the
discharge temperature sensor;
2. Re
place the discharge
te
mperature sensor;
3.Replace the outdoor control
board.
18 AC voltage is
abnormal
1.
The AC voltage>275V or <160V
;
2.
The AC voltage of sampling circuit
on the driver board is abnormal
.
1.
Normal protection, please
check the supply power;
2.
Replace the driver board.
19 Suction temperature
sensor fault
1.
The wiring of the suction
tempe
-
r
ature sensor
is
connect
ed
loose
ly
;
2.
The suction temperature sensor
fail
s
;
3.
The sampling circuit is abnormal
.
1.Reconnect the wiring of the
suction temperature sensor;
2.Replace the suction
temperature sensor;
3.Replace the outdoor control
board.
22 The defrosting sensor
fault
1.
The wiring of the defrosting sensor
is
connect
ed
loose
ly
;
2.
The defrosting sensor fail
s
;
3.
The sampling circuit is abnormal
.
1. Reconnect the wiring of the
defrosting sensor;
2. Replace the defrosting sensor;
3. Replace the outdoor control
board.
45 IPM fault
There are many reasons for this
failure
.
You can check the driver
board
fault
LED to
further
a
naly
ze
the fault code of the drive board and
to learn about what leads to the fault
and how to operate it
. Specific
information can be
see
n in
table 5,
table 6.
See attached "analysis of the
driving board fault".
22
2. The discharge temperature sensor
fails;