- 83 -
CODE
FAULT
CAUSE
SOLUTION
0x48 XY out of range
1. There is a message outside the print
area.
2. The encoder signal may contain
noise.
1. Move messages so that all messages
are placed in the print area.
2. Check if there is a noise source
arround. If there is a noise source,
remove the noise. Please read
“Chapter 0. WARNING” to improve
noise resistance.
0x54 RTC battery failure
1. The voltage of the coin battery is low. 1. Replace the coin battery.
0x63 FPGA failure
1. It may have been affected by external
noise during use.
1. Please restart the Laser Marker.
2. In this environment, the same error
may occur again. Read “Chapter 0.
WARNING” to improve
noise
resistance and do not touch the
connector on the back of the LM during
operation. (The human body is also a
source of electrostatic noise.)
0x65 Shutter not open
1. The shutter is closed.
1.
Check if the sensor lamp of the optical
box is switched by opening and closing
the shutter. If not, the board may be
damaged. Please contact your
HITACHI distributor.
The user is not always informed of all alarms when there is a failure. The user needs to decide whether
or not to have the system report the following alarms:
Belt Stop
Over Speed
Trigger signal
Laser Interlock
Shutter closed
Empty message
OEM Shutter
Maximum distance alarm
Minimum distance alarm
The alarms other than the above always report failures to the user.
Содержание LM-C300 Series
Страница 67: ... 67 4 2 3 DIMENSIONS LM C330S P LM C310S P ...
Страница 68: ... 68 LM C311P LM C331S P ...