Ensure that all electrical wiring, connections and grounding comply with
applicable codes. Properly connect the Laser Marker to its dedicated ground.
Complete the above procedure to avoid electrical shock hazards.
If an extraneous noise enters the Laser Marker, it may cause a malfunction or a
breakdown.
For maximum noise immunity, observe the following installation and
wiring precautions:
• Ensure that 100 to 120 VAC or 200 to 24
0 VAC power cables are not bundled
with other power supply cables.
• Insulate the
Laser Marker main body and the touch screen so that they do not
come into direct contact with the conveyor or other devices.
• If the employed print target detector is housed
in a metal case, use a plastic
mounting piece for the purpose of insulating the detector from the conveyor and
other devices.
• Be sure that the print target detector wiring is not bundled together with other
power supply cables.
Grounding
WARNING
Installation Environment
CAUTION