Output Summary Table
- This table shows all 12 functions (13 for –xFU2 models) for the
logic outputs terminals [11] and [12] at a glance. Detailed function descriptions, related param-
eters and settings, and example wiring diagrams are in
“Using Intelligent Output Terminals” on
.
Output Function Summary Table
Option
Code
Terminal
Symbol
Function Name
Description
00
RUN
Run signal
ON
Inverter is in Run Mode, motor running
OFF
Inverter is in Stop Mode, motor stopped
01
FA1
Frequency arrival type
1 – constant speed
ON
when output to motor is at the standard set frequency
F001
OFF
when output to motor is not at the set frequency F001
02
FA2
Frequency arrival type
2 – over-frequency
ON
when output to motor is at or above the FA threshold
1(C042) during accel
OFF
when the output to motor is below the FA threshold 1
(C043) during decel
03
OL
Overload advance
notice signal
ON
when output current is more than the set threshold for
the overload signal (set with C041)
OFF
when output current is less than the set threshold for
the overload signal
04
OD
Output deviation for
PID control
ON
when PID error is more than the set threshold for the
deviation signal
OFF
when PID error is less than the set threshold for the
deviation signal
05
AL
Alarm signal
ON
when the alarm condition has been met and not reset
OFF
when the alarm had not tripped since the previous
power cycle or since the previous keypad reset
06
FA3
Frequency arrival type
3 – at frequency
ON
when output to motor is at the FA threshold 1 (C042)
during accel, or at C043 during decel
OFF
when the output to motor is not at either the FA
threshold 1 (C042) during accel or at C43 during
decel
08
IP
Instantaneous power
failure signal
ON
when the inverter input power has decreased below
the acceptable input voltage level
OFF
when the inverter input power is within rated range
09
UV
Under-voltage signal
ON
when the inverter input power has decreased below
the acceptable input voltage level
OFF
when the inverter input power is within rated range
11
RNT
Operation time over
ON
when the inverter Run time exceeds the limit set by
Run/power-on warning time (B034)
OFF
when the inverter Run time is less than the limit set by
Run/power-on warning time (B034)
12
ONT
Plug-in time over
ON
when the inverter plug-in time exceeds the set limit
OFF
when the inverter plug-in time is less than the limit
Содержание L300P Series
Страница 2: ......
Страница 42: ......
Страница 134: ......
Страница 195: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 6 5 ...
Страница 225: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 6 A ...
Страница 250: ......
Страница 251: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 263: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 4 D ...
Страница 272: ......