4. CHECKING THE HARDWARE STATUS
4-5
(1) List of displayed icons and description of each icon
Table 4-1 shows a list of displayed icons and a description of each icon. A description of
the displayed icon is shown when you point the mouse cursor to the icon.
Table 4-1 Hardware Status Icon
No.
Hardware
status
Icon
Description of the icon
1
Normal
Hardware status is normal.
2
Error
Fan failed.
3
Abnormal TEMP detected.
4
Fan failed. Abnormal TEMP detected.
5
Fan failed. Drive failure possible.
6
Abnormal TEMP detected. Drive failure possible.
7
Fan failed. Abnormal TEMP detected. Drive failure possible.
8
Fan failed. Time of drive exceeded.
9
Abnormal TEMP detected. Time of drive exceeded.
10
Fan failed. Abnormal TEMP detected. Time of drive exceeded.
11
RAID error detected.
12
Fan failed. RAID error detected.
13
Abnormal temperature detected. RAID error detected.
14
Fan failed. Abnormal temperature detected. RAID error detected.
15
Caution
Drive failure possible.
16
Time of drive exceeded.
Nos. 5 through 7 and 15: When both “Time of drive exceed.” and “Drive failure possible.” happen at the
same time, the description of the icon does not show “Time of drive exceeded.”
Nos. 11 through 14: These descriptions apply to D Model only. When both “Drive failure possible.” (or
“Time of drive exceeded.”) and disconnection of a drive due to RAID error
(OFFLINE) happen at the same time, the description of the icon does not show “Drive
failure possible.” (or “Time of drive exceeded.”).
Nos. 15 and 16: If a hardware status error is detected at the same time, the icon for a hardware status error
is displayed.
Содержание HF-BT1000
Страница 1: ...BT 63 0004 01 ...
Страница 2: ...BT 63 0004 01 ...
Страница 15: ...This Page Intentionally Left Blank ...
Страница 79: ...This Page Intentionally Left Blank ...
Страница 103: ...This Page Intentionally Left Blank ...
Страница 111: ...This Page Intentionally Left Blank ...
Страница 127: ...This Page Intentionally Left Blank ...
Страница 129: ...This Page Intentionally Left Blank ...