1. CAPABILITIES OF THE RAS FEATURE
1-3
(5) Event notification
Enables a user application to check the hardware status of this equipment by monitoring the
status of event objects.
(6) Popup notification
Notifies a user that an error occurred in the hardware of this equipment by displaying popup
messages.
(7) Status display digital LEDs
The status display digital LEDs are on the front of this equipment and notify a user that an
error occurred in the hardware of this equipment. These LEDs can be used by a user
application in order to, for example, notify the failure of the application.
(8) Remote notification
Enables a remote device to check the hardware status of the equipment. This function also
notifies to a remote device whenever the hardware status changes.
(9) Status acquisition using library functions
This function enables a user application to get the hardware status of this equipment by using
the RAS library.
<Control>
(10) Automatic shutdown
Automatically shuts down the equipment when fan failure or abnormal temperature inside the
chassis. Use “(3) RAS Setup window” to enable or disable the automatic shutdown feature.
(11) System reset
The system resets when a watchdog timer timeout in the equipment is detected. Use “(3) RAS
Setup window” to enable or disable the system reset feature.
(12) Shutdown using library functions
A user application can shut down the equipment using the RAS library.
(13) Controlling the status display digital LEDs
Enables a user to control the status display digital LEDs with the RAS library.
<Library functions>
(14) RAS library interface
Offers library functions for recording log information in addition to the library functions
offered by (2), (9), (12), and (13).
<Maintenance / Failure analysis>
(15) Memory dump collection
When a failure occurs, for example, this equipment stops unexpectedly, you can save the
contents of the system memory to a file (memory dump file) by pressing
Scroll Lock
twice
while holding the right
Ctrl
key. By analyzing the data in this memory dump, you can
investigate the cause of the failure.
Содержание HF-BT1000
Страница 1: ...BT 63 0004 01 ...
Страница 2: ...BT 63 0004 01 ...
Страница 15: ...This Page Intentionally Left Blank ...
Страница 79: ...This Page Intentionally Left Blank ...
Страница 103: ...This Page Intentionally Left Blank ...
Страница 111: ...This Page Intentionally Left Blank ...
Страница 127: ...This Page Intentionally Left Blank ...
Страница 129: ...This Page Intentionally Left Blank ...