horcmstart 100 101
starting HORCM inst 100
HORCM inst 100 starts successfully.
starting HORCM inst 101
HORCM inst 101 starts successfully.
2
.
Confirm the P-VOL's virtual LDEV ID.
raidcom get ldev -ldev_id 0x2222 -key front_end -cnt 1 -fx -IH100
Serial# LDEV# SL CL VOL_TYPE VOL_Cap(BLK) PID
ATTRIBUTE Ports PORT_No:LU#:GRPNAME ...
311111 2222 0 0 OPEN-V-CVS 1024000 0
CVS|HDP 0
3
.
Check that the same virtual LDEV ID as that of the primary volume does
not exist in the virtual storage machine of the secondary site. After you
execute this command, if virtual LDEV ID 0x2222 is not displayed, the
same virtual LDEV ID (0x2222) as that of the primary volume does not
exist in the virtual storage machine of the secondary site.
raidcom get ldev -ldev_id 0x2222 -key front_end -cnt 1 -fx -IH101
When you specify the virtual storage machine for HORCM_VCMD in the
configuration definition file and execute the
raidcom get ldev
command
by specifying the
-cnt
option, the virtual LDEV IDs in the range specified
by the
-cnt
option are displayed.
Tip:
To display the volume information as a list for each volume, use the
-key front_end
option for the
raidcom get ldev
command.
Revising the virtual LDEV ID in the virtual storage machine of the secondary site
If the same virtual LDEV ID as that of the primary volume is displayed for the
virtual storage machine of the secondary site, there might be errors in the
GAD system establishment plan. Revise the system configuration.
The example when the same virtual LDEV ID as that of the P-VOL (0x2222) is
assigned to the volume (LDEV ID: 0xfefe) in the virtual storage machine of
the secondary storage machine is shown below.
Procedure
1
.
Check whether the same virtual LDEV ID as that of the primary volume is
assigned to the virtual storage machine of the secondary site.
raidcom get ldev -ldev_id 0x2222 -key front_end -cnt 1 -fx -IH101
Serial# LDEV# SL CL VOL_TYPE VOL_Cap(BLK) PID ATTRIBUTE Ports
PORT_No:LU#:GRPNAME ...
311111 2222 - - NOT DEFINED
The virtual LDEV ID (0x2222) is assigned to the virtual storage machine
of the secondary site.
2
.
Confirm the actual LDEV ID of the volume whose virtual LDEV ID is
0x2222.
raidcom get ldev -ldev_id 0x2222 -fx -IH101
Serial# : 311111 PHY_Serial# : 322222
LDEV : 2222 PHY_LDEV : fefe
SL : -
CL : -
4-44
Configuration and pair management using CCI
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Содержание G1000
Страница 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 60: ...2 22 System requirements Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 80: ...3 20 Planning for global active device Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 128: ...4 48 Configuration and pair management using CCI Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...