For details about the error codes issued by the CCI configuration definition
command (raidcom), see the
Hitachi Command Control Interface User and
Reference Guide.
If the problem persists, send the contents of the /HORCM/log* folder to
Hitachi Data Systems customer support.
Table 9-1 Error codes and details when operating CCI (when SSB1 is 2E31,
B901, B90A, B90B, B912 or D004)
Error code
(SSB2)
Details
9100
The command cannot be executed because user authentication has not
been performed.
B952
The specified LU is not defined. A configuration of the storage system might
have been changed. Restart CCI.
B9A2
You cannot create the GAD pair because the specified volume is a
command device.
B9A3
You cannot create the GAD pair because the specified volume is a
mainframe volume.
B9A4
You cannot create the GAD pair because no SCSI path is defined on the
specified volume.
B9A5
You cannot create the GAD pair or perform a swap resync for the pair
because one of the following remote paths is not set.
•
A bidirectional remote path between the storage systems at the
primary site and secondary site
•
A remote path from the storage system at the primary site to the
storage system at the secondary site
•
A remote path from the storage system at the secondary site to the
storage system at the primary site
B9BD
A configuration of the LDEV in the storage system might have been
changed while CCI was running. Restart CCI.
B9C0
There are no free resources in the command device. Use LUN Manager to
turn off and then turn on the command device.
DB89
You cannot change the status of the GAD pair even though a request to
suspend or to delete the pair has been received. This is because the
volume paired with the specified volume is in an unusable status.
DB8A
You cannot change the status of the GAD pair even though a request to
suspend or to delete the pair has been received. This is because the
volume paired with the specified volume is blocked.
DB8B
You cannot change the status of the GAD pair even though a request to
suspend or to delete the pair has been received. This is because the
volume paired with the specified volume is in an unusable status.
DB8D
You cannot change the status of the GAD pair even though a request to
suspend or to delete the pair has been received. This is because the
number of remote paths from the storage systems at the primary site to
the storage systems at the secondary site is less than the minimum
number of remote paths.
9-8
Troubleshooting
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Содержание G1000
Страница 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 60: ...2 22 System requirements Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 80: ...3 20 Planning for global active device Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 128: ...4 48 Configuration and pair management using CCI Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...