Go to the next step even if the alternate path cannot be deleted.
2
.
Delete the pair.
a
.
From the secondary storage system, delete the pair specifying the
actual LDEV ID of the S-VOL.
pairsplit -g oraHA -R -d dev1 -IH1
Note:
To delete the pair specifying the S-VOL, use the -R option of
the pairsplit command. Specify the actual LDEV ID (device name) of
the S-VOL in the -d option.
b
.
Confirm that the pair is deleted.
pairdisplay -g oraHA -fxce -IH1
Group PairVol(L/R) (Port#,TID, LU), Seq#, LDEV#.P/
S,Status,Fence, %, P-LDEV# M CTG JID AP EM E-
Seq# E-LDEV# R/W
oraHA dev1(L) (CL1-C-0, 0, 0)322222 4444.SMPL ----
------, ----- ----- - - - - - - -
-/-
oraHA dev1(R) (CL1-A-0, 0, 0)311111 2222.SMPL ----
------, ----- ----- - - - - - - -
-/-
3
.
Remove the failure.
The following example shows recovery from a pool-volume failure.
a
.
Recover a pool volume that configures the P-VOL (DP-VOL).
b
.
Display the status of the pool volumes to confirm that the pool volume
has been recovered.
raidcom get ldev -ldev_list pool -pool_id 0 -IH0
(snip)
LDEV : 16384
(snip)
STS : NML
(snip)
For a normal volume,
NML
is indicated in the
STS
column.
4
.
If the volume cannot be recovered, follow the procedure below to re-
create the P-VOL:
a
.
At the primary storage system, delete the LU path to the P-VOL.
b
.
Delete the P-VOL.
c
.
Create a new volume.
d
.
Set an LU path to the new volume.
5
.
Recreate the pair.
a
.
If you created a volume in step 4, set the GAD reservation attribute to
the created volume.
raidcom map resource -ldev_id 0x2222 -virtual_ldev_id reserve
-IH0
b
.
From the secondary storage system, create the pair specifying the S-
VOL's actual LDEV ID.
paircreate -g oraHA -f never -vl -jq 0 -d dev1 -IH1
6-14
Disaster recovery of global-active device
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Содержание G1000
Страница 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 60: ...2 22 System requirements Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 80: ...3 20 Planning for global active device Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 128: ...4 48 Configuration and pair management using CCI Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...