8 APPENDIXES
8-66
8.6.2 10BASE-T (UTP) cable
(1) Preparing a 10BASE-T (UTP) able
①
Removing the covering (sheath) from the 10BASE-T (UTP) cable
Cut about 40 mm of sheath and then loosen the wire strands to rearrange them in proper
order.
Under normal conditions, a normal cable (straight cable) should be used.
Arrangement
T568B T568A
Normal Cross
8 Brown Brown
7 White/brown
White/brown
6 Green Orange
5 White/blue White/blue
4 Blue
Blue
3 White/green White/orange
2 Orange
Green
1 White/orange
White/green
Figure 8-70 Removing the UTP Cable Sheath
②
Cutting the 10BASE-T (UTP) cable signal wires
With nippers or the like, cut the cable in such a manner that about 14 mm of signal wires
protrudes out of the remaining sheath.
Figure 8-71 Cutting the UTP Cable Signal Wires
40 mm
14 mm