5 USER GUIDE
5-121
Token hold time (ms): Token holding time of the self-node
Token hold time = 1.6 + 0.0036 × S + 0.0029 × R + 2.47 × F + MFT
..............[When 0
≤
MFT < 2 and R
≤
512]
Token hold time = 1.6 + 0.0036 × S + 0.0029 × R + 2.47 × F
..............[When 0
≤
MFT < 2 and R > 512]
Token hold time = 1.6 + 0.0036 × S + 0.0029 × R + (0.87 + MFT) × F + MFT
..............[When MFT
≥
2 and R
≤
512]
Token hold time = 1.6 + 0.0036 × S + 0.0029 × R + (0.87 + MFT) × F
..............[When MFT
≥
2 and R > 512]
Refresh cycle time (ms):
Sum of the token hold time values of all the nodes.
Refresh cycle time = 1.6 × n + 0.0065 × W + 2.47 × (F1 + F2 + F3....... + Fn) + MFT × n
.............[When
0
≤
MFT < 2 and R
≤
512]
Refresh cycle time = 1.6 × n + 0.0065 × W + 2.47 × (F1 + F2 + F3....... + Fn)
.............[When
0
≤
MFT < 2 and R > 512]
Refresh cycle time = 1.6 × n + 0.0065 × W + (0.87 + MFT) × (F1 + F2 + F3 ...... + Fn) + MFT × n
.............[When
MFT
≥
2 and R
≤
512]
Refresh cycle time = 1.6 × n + 0.0065 × W + (0.87 + MFT) × (F1 + F2 + F3 ...... + Fn)
.............[When
MFT
≥
2 and R > 512]
Cyclic transfer throughput (ms)
Time from setting data in the memory of the transmitting side CPU to calculation by the
ladder program of the receiving side CPU.
Cyclic transfer throughput = RCT + SCT ...........................................[For ladder processing]
Cyclic transfer throughput = RCT .......................................................[For C mode processing]
Содержание FL.NET
Страница 1: ......
Страница 2: ......
Страница 29: ...1 OVERVIEW ...
Страница 33: ...2 FL NET MODULE ...
Страница 42: ...3 FL NET MODULE INSTALLATION ...
Страница 46: ...4 FL NET MODULE WIRING PROCEDURES ...
Страница 53: ...5 USER GUIDE ...
Страница 203: ...5 USER GUIDE 5 151 Sample printout ...
Страница 206: ...6 MAINTENANCE ...
Страница 210: ...7 TROUBLESHOOTING ...
Страница 225: ...8 APPENDIXES ...