3. Cleaner, carburetor and insulator
(1) Disassembly
Loosen the Cover Fixing Bolt
[82]
, and then remove the Cleaner Cover
[81]
and Cleaner Element
[80]
.
Loosen two Screws M5 x 68
[76]
, and then remove the Cleaner Body
[72]
, Carburetor
[26]
, and other
parts. Loosen the Bolt M5 x 30
[22]
, and then remove the Insulator
[21]
and other parts.
(2) Reassembly
Mount the removed parts in the order shown in the figure below. Before mounting the Cleaner Element
[80]
in the Cleaner Cover
[81]
, wash the Cleaner Element
[80]
with gasoline, and then dry it well.
• Cleaner, carburetor and insulator
[20]
[19]
[21]
[22]
[23]
[24]
[25]
[26]
[74]
[75]
[76]
[76]
[80]
[81]
[82]
[72]