3 Servicing
Cycle components
SMGB0120 rev.0 - 11/2017
64
6
Remove the 8 screws fixing the compressor.
Unscrew the screws fixing the structure
(HEX10), as shown in the picture
Screws
(x8)
Right side. From E Box
Left side. From E Box
7
Remove the “U” rod, fix to the structure.
Screw
“U”Rod
8
Use a portable crane or a lift truck to remove
the compressor: Introduce the forks under
the compressor supports and gently pull
backwards.
!
C A U T I O N
Compressor is heavy, two persons and a portable crane or similar are required.