![Hitachi 8E040341 Скачать руководство пользователя страница 121](http://html.mh-extra.com/html/hitachi/8e040341/8e040341_service-manual_21085121.webp)
4 Troubleshooting
Troubleshooting by alarm code
SMGB0120 rev.0 - 11/2017
113
4
Alarm code
03-03
CPU—I/O transmission
Alarm stop reason
Transmission is not performed correctly between CPU PCB(PCBc) and I/O PCB (PCBd).
PCB monitoring position
PCBc (CPU PCB) CN1~PCBd (I/O PCB) CN21 (H-LINK transmission)
Set DSW correctly and
reactivate power supply
Set DSW correctly and
reactivate power supply
Set DSW correctly and
reactivate power supply
Check PCBc (CPU PCB)
and PCBd (I/O PCB)
DSW2-1,2# of
PCBd (I/O PCB) are
correctly set
Yes
Yes
Yes
DSW1-5,6# of
PCBa (Setting PCB)
are correctly set
No
No
No
Terminal
resistance correctly
set. Either DSW8-1# of
PCBc (CPU PCB) or DSW300-
1# of PCBd (I/O PCB)
are set ON