![Hioki PW3336-01 Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/hioki/pw3336-01/pw3336-01_instruction-manual_2137351086.webp)
3.5 Measuring Efficiency
80
In this example, we will measure the input-output efficiency (energy conversion efficiency) of a 3-phase/3-wire
inverter with DC input and AC output. The input side of the inverter will be input to CH3 of the instrument, and
the output side will be input to CH1 and CH2 of the instrument.
Measuring the input-output efficiency of a DC-to-AC (3-phase/3-wire)
inverter
1
Press
and set the wiring mode to
[
3P3W&1P2W
].
In this case, the switching power supply’s input and
output efficiency can be calculated as
η
2(=|Psum|/|P3|×100 [%]), so set the display param-
eter to
η
2.
2
Press
or
to display [
sum
]
[
W
] (Psum) for [
ACDC
] in area a on the
display.
Press
or
to display [
CH3
]
[
W
] (P3) for [
ACDC
] in area b on the dis-
play.
Press
to display [
η
2
] in area c on
the display.
Output side (AC, 3P3W)
Input side (DC, 1P2W)
Inverter
Содержание PW3336-01
Страница 2: ......
Страница 6: ...Contents iv...
Страница 16: ...Operating Precautions 10...
Страница 32: ...1 4 Measurement Workflow 26...
Страница 44: ...2 7 Turning Off the Instrument 38...
Страница 180: ...5 6 Wiring Specifications 174 3 3 phase 3 wire 3P3W 3P3W2M 4 3 phase 3 wire 3V3A 3P3W3M Current sensor...
Страница 181: ...5 6 Wiring Specifications 175 5 3 phase 4 wire 3P4W Current sensor...
Страница 182: ...5 6 Wiring Specifications 176...
Страница 199: ...Appendix 4 Dimensional Diagram A13 e g PW3337 03 Appendix 4 Dimensional Diagram Unit mm...
Страница 200: ...Appendix 4 Dimensional Diagram A14...
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 206: ......