![Hioki PW3336-01 Скачать руководство пользователя страница 155](http://html1.mh-extra.com/html/hioki/pw3336-01/pw3336-01_instruction-manual_2137351155.webp)
5.3 Measurement specifications
149
Window function
Rectangular
Analysis window width
Data update rate
Depends on window width.
Maximum analysis order
Synchronization frequency range: 10 Hz to 640 Hz
Analysis order upper limit
setting
2nd to 50th
Measurement accuracy
f.s.: Measurement range
Frequency (f)
Window width
45 Hz
≤
f < 56 Hz
178.57 ms to 222.22 ms (10 cycles)
56 Hz
≤
f < 66 Hz
181.82 ms to 214.29 ms (12 cycles)
Frequencies other than the above
185.92 ms to 214.08 ms
Synchronization frequency (f) range
Analysis order
10 Hz
≤
f < 45 Hz
50th
45 Hz
≤
f < 56 Hz
50th
56 Hz
≤
f
≤
66 Hz
50th
66 Hz < f
≤
100 Hz
50th
100 Hz < f
≤
200 Hz
40th
200 Hz < f
≤
300 Hz
25th
300 Hz < f
≤
500 Hz
15th
500 Hz < f
≤
640 Hz
11th
For DC, add ±1 mA to current and (±1 mA) × (voltage read value) to active power.
Frequency (f)
Voltage, Current, Active power
DC
±
0.4%rdg.
±
0.2%f.s.
10 Hz
≤
f < 30 Hz
±
0.4%rdg.
±
0.2%f.s.
30 Hz
≤
f
≤
400 Hz
±
0.3%rdg.
±
0.1%f.s.
400 Hz < f
≤
1 kHz
±
0.4%rdg.
±
0.2%f.s.
1 kHz < f
≤
5 kHz
±
1.0%rdg.
±
0.5%f.s.
5 kHz < f
≤
8 kHz
±
4.0%rdg.
±
1.0%f.s.
Содержание PW3336-01
Страница 2: ......
Страница 6: ...Contents iv...
Страница 16: ...Operating Precautions 10...
Страница 32: ...1 4 Measurement Workflow 26...
Страница 44: ...2 7 Turning Off the Instrument 38...
Страница 180: ...5 6 Wiring Specifications 174 3 3 phase 3 wire 3P3W 3P3W2M 4 3 phase 3 wire 3V3A 3P3W3M Current sensor...
Страница 181: ...5 6 Wiring Specifications 175 5 3 phase 4 wire 3P4W Current sensor...
Страница 182: ...5 6 Wiring Specifications 176...
Страница 199: ...Appendix 4 Dimensional Diagram A13 e g PW3337 03 Appendix 4 Dimensional Diagram Unit mm...
Страница 200: ...Appendix 4 Dimensional Diagram A14...
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 206: ......