74
PW3335A985-01
Measurement
Item
Rectificati
on Method
Type
Parameter List
Substitute parameter
(can be used with the
same definition)
(total sum)
During Auto-range integration
operation: Data by current range
(See Note 2.)
IHDC_200mA, IHDC_500mA,
IHDC_1A,IHDC_2A,IHDC_5A,
IHDC_10A, IHDC_20A, IHDC_BACKUP
Integration
time
-
Instantaneous value
TIME
During Auto-range integration
operation: Data by current range
(See Note 2.)
TIME_200mA, TIME_500mA,
TIME_1A,TIME_2A,TIME_5A,
TIME_10A, TIME_20A, TIME_BACKUP
List of Directly Specified :MEASure? Query Items
Note:
U
→
, V, I→A, P→W, S→VA, Q→VAR, IH→AH, PWP→PWH, MWP→MWH, WH→WP,
and
WH→INTEG
are all valid substitutions.
For example,
:MEAS? U
and
:MEAS? V
produce the same response. However,
U
is always returned as the header.
Note 2: Valid only when Auto-range integration is on.
Note 3: Valid only when Auto-range integration is off.
www.
.com