21
Specifications
Specifications
General specifications
Operating environment
Indoors, pollution degree 2, altitude up to 2000 m (6562 ft.)
Operating temperature and
humidity
According to the operating temperature and humidity, and accuracy guarantee for
temperature and humidity of connectable measuring equipment.
Storage temperature and
humidity
−10°C to 50°C (14°F to 122°F), 80% RH or less (no condensation)
Dimensions
Approx. 135W × 82H × 53D mm (5.31″W × 3.23″H × 2.09″D)
Without including the projections of W direction
D direction has the dimensional change according to the shape and tip pin at the
time of DUT measurement.
Mass
Approx. 200 g (7.1 oz.)
Product warranty period
1 year
Accessories and options
Measurement specifications
Basic specifications
Connectable measurement
devices
Models IM7580, IM7580A, IM7581, IM7583, IM7585 (as of July, 2016)
For updated information, please contact your authorized Hioki distributor or reseller.
Connecting part to the
DUT
Bottom surface contact due to 2 terminals structure
Dimensions of measurable
DUT
JIS (EIA):
L × W mm
H mm
0603 (0201):
(0.6±0.03) × (0.3±0.03) mm
H ≥ 0.25 mm
1005 (0402):
(1.0±0.1) × (0.5±0.1) mm
H ≥ 0.4 mm
1608 (0603):
(1.6±0.15) × (0.8±0.1) mm
H ≥ 0.4 mm
2012 (0805):
(2.0±0.15) × (1.25±0.15) mm
H ≥ 0.4 mm
3216 (1206)*:
(3.2±0.15) × (1.6±0.15) mm
H ≥ 0.4 mm
3225 (1210):
(3.2±0.15) × (2.5±0.15) mm
H ≥ 0.4 mm
* The measurement unit of size 3225 (1210) is used for size 3216 (1206).
Used frequency range
DC to 3 GHz
Maximum applied voltage
±42 V peak
Electrical length
19 mm
Connector
7 mm connector
Additional error (representative values)
Applied conditions for
additional errors
•
According to the guaranteed conditions for the accuracy of the connectable
measurement devices.
•
Connectable measuring devices execute open calibration, short calibration, and
load calibration on the 7 mm connector surface through the Model IM9906 Adapter
(3.5 mm/7 mm).
•
Set the electrical length the 19 mm on the connectable measurement device.
•
Connect this device to the connectable measurement device through the adapter
and execute open correction and short correction.
Additional error
(Errors added to the
accuracy specifications
of the connectable
measurement devices)
Impedance: ±Ze [%]
Phase:
θ
e = ±0.58 × Ze [°]
Ze = Ae + (Zse / Zx + Yoe × Zx) × 100
Zx:
Impedance measurement value [
Ω
]
Ae:
4 × f
2
[%]
Zse:
(100 + 500 × f) /1000 [
Ω
]
Yoe:
(10 + 100 × f) /1000000 [s]
f [GHz]
Residual parameters (representative values)
Short plate’s inductance
(at 3 GHz)
0603 (0201): 0.7 nH, 1005 (0402): 0.5 nH, 1608 (0603): 0.7 nH,
2012 (0805): 0.5 nH, 3225 (1210): 0.5 nH
9
8
7
6
5
4
3
2
1
Appx.
Index