1.2 Major Features
Action at memory full: Continue recording (Endless)
3P4W
Recording Mode
Instantaneous
Value
MAX/MIN/AVE
Instantaneous
Value +
MAX/MIN/AVE
Quantity of
storable data
8800
3500
2700
Recording interval
1 sec.
2 hours
0.5 hours
0.5 hours
2 sec.
4.5 hours
1.5 hours
1.5 hours
5 sec.
12 hours
4.5 hours
3.5 hours
10 sec.
1 day
9.5 hours
7.5 hours
15 sec.
1.5 days
14.5 hours
11 hours
20 sec.
2 days
19.5 hours
15 hours
30 sec.
3 days
1.5 days
22.5 hours
1 min.
6 days
2 days
1.5 days
2 min.
12 days
4 days
3.5 days
5 min.
30 days
12 days
9 days
10 min.
61 days
24 days
18 days
15 min.
92 days
36 days
28 days
20 min.
123 days
49 days
37 days
30 min.
184 days
73 days
56 days
60 min.
369 days
147 days
113 days
When the alarm log is ON, the higher the number
of alarms generated, the smaller the recording
period. (Approx. 1/2 of the data per alarm)