5.1 Basic Specifications
42
Voltage / Current measurement
Current range
Measurement
Range
Voltage: U1,U2,U3 100 V,200 V
(Switched using the SW.)
Current: I1,I2,I3
1A,5A,50A,100A,200A,500A,1000A
(Depends on the clamp sensor
used.)
Measurement
Accuracy
Voltage : ±1.0%f.s.
Current : ±1.0%f.s. + Clamp sensor accuracy
Clamp Sensor and Its
Current Range
2331-20 Current Range
(Selectable using the PC
application)
1 A (100 mV/A)
1 A
9765 5 A (20 mV/A)
5 A
9695-02 50 A (10 mV/A)
5 A
50 A
9695-03 100 A (1 mV/A)
100 A
9661-01 500 A (1 mV/A)
100 A
500 A
1000 A (0.5 mV/A)
200 A
1000 A