49
5.3 General Specifications
Withstanding
Voltage
3.536 kVAC Between U INPUT terminals
and Case
(excluding terminal section)
2.210 kVAC Between U INPUT terminals
and ALARM terminals,
interface terminals
CLAMP SENSOR INPUT
terminals and ALARM
terminals, Interface terminals
(50/60 Hz, Response current
5 mA, one minutes
Dimensions
Approx. 45.5W × 96H × 94.5D mm
(1.79"W × 3.78"H × 3.72"D)
(including cover, excluding projections)
Mass
Approx. 240 g (8.5 oz.) (including cover)
Accessories
Instruction manual ................................... 1
Option
9695-02 CLAMP ON SENSOR (50 Arms)
9695-03 CLAMP ON SENSOR (100 Arms)
9661-01 CLAMP ON SENSOR (500 Arms)
9765* CLAMP ON SENSOR (5 Arms)
(See "When using Model 9765 " (p.10))
9238
CLAMP SENSOR CABLE
All sensors are the voltage-output type.
* Not complied with the CE marking.
Operational
Ranges for
Temperature and
Humidity
0 to 50°C (32 to 122°F), 80%RH or less
(with no condensation)
Temperature and
Humidity Rang-
es for Storage
-10 to 50°C (14 to 122°F), 80%RH or less
(with no condensation)
Location for Use Max. 2000 m (6562-ft.) height, indoors
Standards
Applying
Safety EN61010-1:200
Pollution Degree 2
Measurement Category III,
(anticipated transient overvoltage
4000 V)
EMC
EN61326:1997+A1:1998+A2:2001
CLASS A
Содержание 2331-20
Страница 1: ...INSTRUCTION MANUAL POWER METER 2331 20 MODULE ...
Страница 2: ......
Страница 25: ...21 1 4 Dimension Diagrams 1 4 Dimension Diagrams 94 5 1 103 3 1 103 9 1 110 1 Unit mm 96 1 45 5 1 4 0 5 ...
Страница 26: ...1 4 Dimension Diagrams 22 ...
Страница 28: ...2 1 Setting the Module ID 24 ...
Страница 44: ...4 2 Insulation of Internal Circuit 40 ...
Страница 54: ...5 3 General Specifications 50 ...
Страница 56: ...6 2 Service 52 ...
Страница 57: ......
Страница 58: ......