Technical Data
70/78
COMX Communication Modules | Design Guide
DOC100901DG18EN | Revision 18 | English | 2013-12 | Released | Public
© Hilscher, 2002-2013
4.1.7
COMX 10CA-DNS
Immunity COMX 10CA-DNS
Generic Standard
Basic Standard Test
Test level
Error
Class
Electrostatic Discharge
Air discharge
+ 10 kV
B
EN 61000-4-2
Contact discharge
+ 6 kV
B
Burst
EN 61000-4-4
Communication lines (shielded)
+ 2 kV
B
Surge
EN 61000-6-2 (2006-03)
Industrial Environment
EN 61131-2 (2008-04)+A11, A12
Programmable Controllers
EN 61000-4-5
Communication lines (shielded)
0.5 kV
B
Table 51: Product Tests COMX 10CA-DNS – Immunity
4.1.8
COMX 10CN-DNS
Immunity COMX 10CN-DNS
Generic Standard
Basic Standard Test
Test level
Error
Class
Electrostatic Discharge
Air discharge
+ 10 kV
B
EN 61000-4-2
Contact discharge
+ 6 kV
B
Burst
EN 61000-4-4
Communication lines (shielded)
+ 2 kV
B
Surge
EN 61000-6-2 (2006-03)
Industrial Environment
EN 61131-2 (2008-04)+A11, A12
Programmable Controllers
EN 61000-4-5
Communication lines (shielded)
1 kV
A
Table 52: Product Tests COMX 10CN-DNS – Immunity
4.1.9
COMX 50CA-REFO
Immunity COMX 50CA-REFO
Generic Standard
Basic Standard Test
Test level
Error
Class
Electrostatic Discharge
Air discharge
+ 10 kV
B
EN 61000-4-2
Contact discharge
+ 6 kV
B
Burst
EN 61000-6-2 (2006-03)
Industrial Environment
EN 61131-2 (2008-04)+A11, A12
Programmable Controllers
EN 61000-4-4
Communication lines (shielded)
+ 2 kV
B
Table 53: Product Tests COMX 50CA-REFO – Immunity