Technical Data
71/78
COMX Communication Modules | Design Guide
DOC100901DG18EN | Revision 18 | English | 2013-12 | Released | Public
© Hilscher, 2002-2013
4.1.10 COMX 50CA-CCS
Immunity COMX 50CA-CCS
Generic Standard
Basic Standard Test
Test level
Error
Class
Electrostatic Discharge
Air discharge
+ 8 kV
B
EN 61000-4-2
Contact discharge
+ 4 kV
A
Burst
EN 61000-4-4
Communication lines (shielded)
+ 2 kV
fr = 5 kHz
B
Surge
EN 61000-6-2 (2006-03)
Industrial Environment
EN 61131-2 (2008-04)+A11, A12
Programmable Controllers
EN 61000-4-5
Communication lines (shielded)
1 kV
2 Ohm / 18
μ
F
A
Table 54: Product Tests COMX 50CA-CCS – Immunity
4.1.11 COMX 51CA-RE
Immunity COMX 51CA-RE
Generic Standard
Basic Standard Test
Test level
Error
Class
Electrostatic Discharge
Air discharge
+ 8 kV
A
EN 61000-4-2
Contact discharge
+ 6 kV
B
Burst
EN 61000-4-4
Communication lines (shielded)
+ 2.2 kV
fr = 5 kHz
B
Surge
EN 61000-6-2 (2006-03)
Industrial Environment
EN 61131-2 (2008-04)+A11, A12
Programmable Controllers
EN 61000-4-5
Communication lines (shielded)
1 kV
A
Table 55: Product Tests COMX 51CA-RE – Immunity
4.1.12 COMX 100CA-CO
Immunity COMX 100CA-CO
Generic Standard
Basic Standard Test
Test level
Error
Class
Electrostatic Discharge
Air discharge
+ 10 kV
A
EN 61000-4-2
Contact discharge
+ 6 kV
A
Burst
EN 61000-4-4
Communication lines (shielded)
+ 2 kV
fr = 5 kHz
A
Surge
EN 61000-6-2 (2006-03)
Industrial Environment
EN 61131-2 (2008-04)+A11, A12
Programmable Controllers
EN 61000-4-5
Communication lines (shielded)
1 kV
2 Ohm / 18
μ
F
A
Table 56: Product Tests COMX 100CA-CO – Immunity