Getting Started
36/154
PC Cards cifX PC/104 | Installation, Operation and Hardware Description
DOC120206UM42EN | Revision 42 | English | 2014-12 | Released | Public
© Hilscher, 2008-2014
System
Note
CC-Link Slave
To configure the Master, a CSP file (device description file) is required. The settings in the used
Master must comply with the settings in the Slave to establish communication. Important
parameters are: Slave Station Address, Baudrate, Station Type and Vendor Code.
Table 21: Notes for the Configuration of the Master Device
Further information to the device description files you find under section
on
Device Description Files cifX
page 15.
4.4 Device Names in SYCON.net
The following table contains the device names displayed for the single
communication protocols in the configuration software SYCON.net.
The table shows the PC card cifX and which protocol can be used. Further-
more, the table shows, for which protocol which device must be selected
from the device catalog to configure the PC card cifX with SYCON.net.
PC Cards cifX
Protocol
DTM Specific Group
Device Name in
SYCON.net
EtherCAT Master
Master
CIFX RE/ECM
EtherCAT Slave
Gateway/Stand-Alone Slave
CIFX RE/ECS
EtherNet/IP Scanner (Master)
Master
CIFX RE/EIM
EtherNet/IP Adapter (Slave)
Gateway/Stand-Alone Slave
CIFX RE/EIS
Open-Modbus/TCP Gateway/Stand-Alone
Slave
CIFX
RE/OMB
POWERLINK-Controlled-
Node/Slave
Gateway/Stand-Alone Slave
CIFX RE/PLS
PROFINET IO-Controller
Master
CIFX RE/PNM
PROFINET IO-Device
Gateway/Stand-Alone Slave
CIFX RE/PNS
sercos Master
Master
CIFX RE/S3M
sercos Slave
Gateway/Stand-Alone Slave
CIFX RE/S3S
CIFX 104-RE,
CIFX 104-RE-R
CIFX 104-RE\F
CIFX 104-RE-R\F
VARAN Client (Slave)
Gateway/Stand-Alone Slave
CIFX RE/VRS
PROFIBUS DP Master
Master
CIFX DP/DPM
PROFIBUS DP Slave
Gateway/ Stand-Alone Slave
CIFX DP/DPS
CIFX 104-DP
CIFX 104-DP-R
CIFX 104-DP\F
CIFX 104-DP-R\F
PROFIBUS MPI Device
Gateway/ Stand-Alone Slave
CIFX DP/MPI
CANopen Master
Master
CIFX CO/COM
CIFX 104-CO
CIFX 104-CO-R
CIFX 104-CO\F
CIFX 104-CO-R\F
CANopen Slave
Gateway/ Stand-Alone Slave
CIFX CO/COS
DeviceNet Master
Master
CIFX DN/DNM
CIFX 104-DN
CIFX 104-DN-R
CIFX 104-DN\F
CIFX 104-DN-R\F
DeviceNet Slave
Gateway/ Stand-Alone Slave
CIFX DN/DNS
CIFX 104-CC\F
CC-Link Slave
Gateway/
Stand-Alone Slave
CIFX CC/ CCS
Table 22: Device Names in SYCON.net by Communication Protocol