Hardware Installation and Uninstalling
62/154
PC Cards cifX PC/104 | Installation, Operation and Hardware Description
DOC120206UM42EN | Revision 42 | English | 2014-12 | Released | Public
© Hilscher, 2008-2014
6.5 Uninstalling PC Cards cifX PC/104
1. Take safety precautions.
Lethal Electrical Shock caused by parts with more than 50V!
Disconnect the power plug of the PC or of the connecting device.
Make sure, that the power supply is off at the PC or at the connecting
device.
Electrostatically sensitive Devices
To prevent damage to the PC and the PC card cifX, make sure, that the
PC card cifX is grounded via the endplate and the PC and make sure,
that you are discharged when you install/uninstall the PC card cifX.
2. Remove the connecting cable to the Master or Slave.
Remove the connecting cable between the PC card cifX to be replaced
and the PC card Master or Slave.
3. Open cabinet.
Open the cabinet of the PC or of the connecting device.
Note:
If a PC card CIFX 104-XX\F or CIFX 104-XX-R\F shall be uninstalled from a stack
of PC/104 modules:
(a) Remove all PC/104 modules above from the PC card cifX and the PC card cifX. For
each PC card cifX first remove the AIFX assembly interfaces from the basic cards.
(b) Reinstall the removed PC/104 modules.
Uninstall AIFX Assembly Interfaces
Only for PC cards PC/104 with AIFX Assembly Interface CIFX 104-XX\F
and CIFX 104-XX-R\F:
4. Uninstall the Ethernet assembly interface (AIFX-RE), PROFIBUS
(AIFX-DP), CANopen (AIFX-CO), DeviceNet (AIFX-DN) and diagnostic
(AIFX-DIAG):
Remove the AIFX assembly interfaces from the front plate of the PC
cabinet.
Disconnect the cables from the PC card cifX PC/104; cable connector
Ethernet X4 (or X304) or cable connector fieldbus X4 (or X304) and
cable connector DIAG X3 (or X303).
Remove PC Card cifX
5. Remove PC card cifX
PC/104
.
Loosen the four fastening screws of the PC card cifX.
Remove the PC card cifX.
After this:
6. Close cabinet.