Technical Data
101/154
PC Cards cifX PC/104 | Installation, Operation and Hardware Description
DOC120206UM42EN | Revision 42 | English | 2014-12 | Released | Public
© Hilscher, 2008-2014
CIFX 104-RE\F,
CIFX 104-RE-R\F
Parameter
Value
For Open Modbus/TCP with V2.3.4.0 and higher both
RJ45 channels can be used.
Diagnostic Assembly Interface
AIFX-DIAG, refer to section
AIFX-DIAG
, page 117.
Note:
If the diagnostic
AIFX-DIAG
assembly interface is
connected to the PC card CIFX 104-RE\F or CIFX 104-
RE-R\F, the
Mini-B USB
connector on the AIFX-DIAG can
be used beginning with the hardware revision 5 of the PC
card cifX.
Diagnosis Interface
Connector AIFX-DIAG
Cable Connector DIAG X3 (X303)
(JST 12FMN-SMT-A-TF(LF)(SN), Pitch 1,0 mm)
SYS
System Status LED
Display LED
Display
For LEDs at AIFX-RE, refer to section
AIFX-RE
, page 112.
Supply Voltage
+5 V dc ±5 %, refer to section
Power Supply and Host
Interface
, page 28.
Maximum Current at
at 5 V (typically)
500 mA
Power supply
Connector
Via PC/104 Bus
Operating temperature range*
0 °C ... +70 °C
*Air flow during measurment
0,5m/s
Storage temperature range
0 °C ... +70 °C
Environmental
Conditions
Humidity
10 … 95% relative humidity, no condensation permitted
Dimensions (L x W x H)
97 x 91 x 24 mm
Mounting/Installation
PC/104 Slot (5 V), refer to section
Slot for the PC Cards
cifX PC/104
, page 28.
Device
RoHS Yes
CE Sign
Yes
Emission
EN 55011:2009 + A1:2010, CISPR 11:2009, Class A
(Radio disturbance characteristics - Limits and methods of
measurement)
CE Sign
Immunity
EN 61000-4-2:2009 (Electrostatic discharge test)
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)
EN 61000-4-8:2010 (power frequency magnetic field test)
EN 61000-6-2:2005 + B1:2011 (for industrial
environments)
Configuration Software
Master and Slave
SYCON.net
Configuration
Configuration Software Slave
netX Configuration Tool
Table 85: Technical Data CIFX 104-RE\F, CIFX 104-RE-R\F