© Hills Industries 2006
Page 57
Appendix 3: Expander Numbers for Reporting Expander Trouble
The tables below list the device numbers that will be reported for each expander/code pad that has a trouble condition if
expanded Contact I.D. is enabled system options.
Code Pads Module Number Table
Code Pad
Area 1
Area 2
Area 3
Area 4
Area 5
Area 6
Area 7
Area 8
1 192 193 194 195 196 197 198 199
2 200 201 202 203 204 205 206 207
3 208 209 210 211 212 213 214 215
4 216 217 218 219 220 221 222 223
5 224 225 226 227 228 229 230 231
6 232 233 234 235 236 237 238 239
7 240 241 242 243 244 245 246 247
8 248 249 250 251 252 253 254 255
NX-216 Zone Expanders
Note: Must power down before changing address/starting zone number
Module
Number
Reported
Starting
Zone
Number
Switch 1
Switch 2
Switch 3
Switch 4
1
st
23 9
ON
OFF OFF
2
nd
16 17 OFF
ON
OFF
3
rd
17 25
ON
ON
OFF
4
th
18 33 OFF
OFF
ON
5
th
19 41
ON
OFF
ON
When
set ON,
disables
upper
8 zones
on
NX-216
module
NX-216E Zone Expanders
new
Note: Must power down before changing address/starting zone number
Module
Number
Reported
Starting
Zone
Number
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
Switch 6
1
st
22
1 OFF OFF OFF OFF OFF
2
nd
23 9
ON
OFF OFF OFF OFF
3
rd
16 17 OFF
ON
OFF OFF OFF
4
th
17 25
ON
ON
OFF OFF OFF
5
th
18 33 OFF
OFF
ON
OFF OFF
6
th
19 41
ON
OFF
ON
OFF OFF
7
th
20 49 OFF
ON
ON
OFF OFF
8
th
21 57
ON
ON
ON
OFF OFF
9
th
96
65 OFF OFF OFF
ON
OFF
10
th
97 73
ON
OFF OFF
ON
OFF
11
th
98 81 OFF
ON
OFF
ON
OFF
12
th
99 89
ON
ON
OFF
ON
OFF
13
th
100 97 OFF OFF
ON
ON
OFF
14
th
101 105
ON
OFF
ON
ON
OFF
15
th
102 113 OFF
ON
ON
ON
OFF
16
th
103 121
ON
ON
ON
ON
OFF
When
set ON,
disables
upper
8 zones
on
NX-216E
module