Page 60
System
Service Light “ON” - Pressing
¹
2 displays LED 1.
Press the (1) key and observe which LED comes on to indicate one of the
following:
1. Over Current Fault
A Partial short circuit on the Aux Pwr, Smoke power,
Horn Speaker, Strobe or
Screamer will cause an over current
faults. (Fuseless design)
Removing the short from the Aux Pwr or Smoke Pwr will
fix the over current condition
immediately.
If the short is on the horn, Strobe or Screamer you must put the panel into alarm
once the fault has been removed to clear the over current condition.
2. Siren Trouble
The Horn Speaker is open / short circuit or not connected.
The Hills Reliance control panel monitors the siren output for faults and tampering. If
a horn speaker is not connected to the panel
place a 3K3 resistor across the Bell
output to disable Siren Trouble Monitoring.
3. Box Tamper
The box tamper pins are open circuit or activated. Ensure the box tamper pins are
sealed (closed circuit). Arm and Disarm
system to clear box tamper condition.
4. Expander Power
An expander connected to the system has a short circuit on
the Aux output.
Expander that can report this condition are power supply (NX320).
5. Expander Low Battery
An expansion device connected to the Hills Reliance system has a Low
Battery
condition. Expander that can indicate low battery conditions: NX320 power supply.
Replace Battery.
6. Expander Box Tamper
An expansion device connected to the Hills Reliance system has a tamper activated.
Check the tamper contacts on the expansion devices connected. Expanders that can
indicate box tamper
:
Code pads, Hardwire zone expanders and Wireless
zone
expanders.
7. Expander Trouble
Code pads are not number correctly (see
¹
94 code pad program)
Expander connected is not seen by system. Enter and Exit program mode.
You are trying to zone double a NX4 panel (not supported)
Only the Hills Reliance 8, Reliance 12, and Reliance 128 can be zone doubled.
Any device connected to the data terminal on the Hills Reliance system can cause an
expander trouble condition.
8. Reserved
System
Service Light “ON” - Pressing
¹
2 displays LED 2.
Zone Tamper has been activated. Press the (2) key and the zone(s) that activated
the tamper will be displayed. Press the (#) key twice to exit. Press
¹
7 is reset
tamper condition.
Service Light “ON” - Pressing
¹
2 displays LED 3.
Low Battery (wireless zones only). Press the (3) key and the wireless zone(s) with
low battery will be displayed. Press
the (#) key twice to exit.