Quick Start Guide
Short form programming sheet for a monitored system
This is not a substitute for reading the manual
1.
Hard Default Panel
Unplug battery & remove power, turn on power,
Enter 971300 within 10 seconds,
Wait 12 seconds
Repeat
2. Go To Program Mode
*8 9713 0#
3.
Soft Default Panel
910#, Exit, Exit, [Chime], wait 12 seconds
4. Go To Program Mode
*8 9713 0#
5. Change Program Code
1# n*n*n*n* #
6. Duress Code
3# n*n*n*n* #
7. Receiver Phone #1
4# n*n*n*n*n*n*n*n* #
8. System Account Code
5# n*n*n*n* #
9. Communication Format
6# 1*
(1 for CID, or 3 for Domestic Dial)
10. Receiver Phone #2
7# n*n*n*n*n*n*n*n* #
11. Report Event Summary
9# 3 7 *#
(for open/close, tamper/restore)
12. Phone Cut Delay
11# n*
13. Download Access Code
12# n*n*n*n*n*n*n*n*
14. Download Control (Remote Access)
14# 1*
(to enable two call AMD)
15. Force Arm Globally
16# 3*#
16. Entry/Exit Time #1 & #2
17# nn*nn*nn*nn* #
17. Configuration Groups (Zone Types)
18#
(zones 1-8)
, 21#
(zones 9-16)
,
59#
(zones 17-24)
, 61#
(zones 25-32)
,
63#
(zones 33-40)
, 65#
(zones 41-48)
,
119#
(zones 49-56)
, 121#
(zones 57-64)
18. System Options
22# 7*7* #
(for siren on tamper and
[*][44] manual communicator test enable)
19. Medical Alarm Sounder “ON”
24# 7*
(enable code pad beeping)
20. Auto Test Control
32#
(see Feature 32 for details)
21. Exit Program Mode
Press Exit, Exit, [Chime] wait 12 seconds
22. Change Master Code (default 1234)
[*5] [Master Code] [01] [New Code] #
23. Program User Codes
[*5] [Master Code] [User] [User Code] #
24. Set Date & Time (at User Level)
Set System Calendar
[*][9][6] [Master Code] [Day of Week]
[Month] [Day of Month] [Year]
Set System Clock
[*][9][7] [Master Code] [Hour] [Minutes]
25. Walk Test
* [Chime] [Master Code]
End Walk Test
[Master Code]
26.
Train Client/End User
Note if testing reporting, master code does not send open/closing reports by default (see Feature 2)