© Hills Industries 2006
Page 61
System
Service Light “ON” - Pressing
¹
2 displays LED 4.
Loss of Supervision (wireless zone only). Press the (4) key and the wireless zone(s)
with Loss of Supervision will be displayed. Press the (#) key twice to exit.
Service Light “ON” - Pressing
¹
2 displays LED 5.
Zone Trouble. Press the (5) key and the zone that has trouble will be displayed. Zone
trouble only applies to Fire type zones. Press the (#) key twice to exit. Press
¹
7 to
reset zone trouble condition.
Service Light “ON” - Pressing
¹
2 displays LED 6.
Telephone line trouble/Line cut, when telephone line is cut from panel.
Service Light “ON” - Pressing
¹
2 displays LED 7.
When light number 7 is lit this indicates that the panel has failed to communicate to
the base station. This led can only be extinguished by communicating to the base.
Check Phone No, Account Code and Format programming.
Press the (#) key twice to exit.
Service Light “ON” - Pressing
¹
2 displays LED 8.
When light 8 is lit this indicates that the panel has lost time. Press the (#) key twice
to exit.
To set system time:
¹
97 (go to program code), enter time (4 digits) Eg 10:30am = 1030