© Hills Industries 2006
Page 33
Segment 4
(1)
On if Fail To Communicate report enabled
2
On if Log Full report enabled
(3)
On if Auto-test report enabled
(4)
On if Start/End programming report enabled
(5)
On if End Download report enabled
(6)
On if Sensor Low Battery report enabled
(7)
On if Sensor Missing report enabled
8
On if Expander Module (number) to be reported via the Contact I.D. report
Segment 5
new
(1)
On enable Lost Clock service light
2
On enables Zone Doubling
3
new
On disables all hardwired zones on the main board.
Must cycle power on/off to disable or re-enable hardwire zones.
4
On will enable all Dual End of Line (DEOL) resistors on all zones
5
On will prevent force armed zones to report bypass
6
On enables Silent Exit option
7
new
Reserved
8
On will Auto Partial Arm Area 1
Segment 6
new
1
new
Enable Two Wire Smoke
2
new
Reserved
3
new
Enable Zone Inactivity Time In Hours
4
new
Reserved
5
new
Reserved
6
new
Reserved
7
new
Enable Steady (Temporal) Siren. Default is off = Evacuation Siren for fire events.
8
new
Reserved
Segment 7
new
1
new
Reserved
2
new
Reserved
3
new
Reserved
4
new
Reserved
5
new
Reserved
6
new
Reserved
7
new
Reserved
8
new
Reserved
System Option Descriptions
Auto Partial Arm Area One
If enabled, area one will auto partial arm at the auto arm time. If this option is enabled, area one cannot be auto armed in
the full mode (see F 22 – Seg 5 – Op 8).
Battery Testing
The Hills Reliance can test for battery presence every 12 seconds (see F 22 – Seg 2 – Op 5).
The Hills Reliance will also test the battery condition at disarm once per 24 hour cycle.
Box Tamper
If enabled, the Hills Reliance will use the N/C Box Tamper pins provided on the main board (see F 22 – Seg 2 – Op 8).
Dual End Of Line (Zone Tamper)
If enabled, the Hills Reliance will monitor all zones except types 17 and 28 for Dual End Of Line. A short or open circuit on a
DEOL will set zone tamper alarms. Refer to the terminal wiring diagram for more detail (see F 22 – Seg 5 – Op 4).
To reset tamper condition press
[
r
]
-
[7]