© Hills Industries 2006
Page 42
Feature 40
new
Area 2 – Entry / Exit Timers
Entry Time 1
Exit Time 1
Entry Time 2
Exit Time 2
Segments 1-6
30
60
30
60
Reserved
new
Reserved
new
Feature 40 sets the primary and secondary entry / exit times for area 2. If all segments in this feature are set to ‘0’, the
entry / exit time for this area will follow area 1 (Feature 17). Valid entries are 10-255 seconds.
Feature 41
new
Area 3 – Account Code
Segments 1-6
10
10
10
10
Reserved
new
Reserved
new
Feature 41 contains the account code sent when area 3 is reported. If Feature 41 is left un-programmed (all ‘10’s), then the
system account code (Feature 5) will be used.
Feature 42
Area 3 – Option and Report Selections
Feature 42 is used to enable certain options that can be accessed or are visible to the user from the code pad of the
system. In addition, certain communicator reports are enabled. Each of these options can be enabled by area 3.
If the option selection feature for any area is left blank, that area will use feature 16 for the option selection. Refer
to Feature 39 in this section for options table.
Feature 43
new
Area 3 – Entry / Exit Timers
Entry Time 1
Exit Time 1
Entry Time 2
Exit Time 2
Segments 1-6
30
60
30
60
Reserved
new
Reserved
new
Feature 43 sets the primary and secondary entry / exit times for area 3. If all segments in this feature are set to ‘0’, the
entry / exit time for this area will follow area 1 (Feature 17). Valid entries are 10-255 seconds.
Feature 44
new
Area 4 – Account Code
Segments 1-6
10
10
10
10
Reserved
new
Reserved
new
Feature 44 contains the account code sent when area 4 is reported. If Feature 44 is left as default (all ‘10’s), then the
system account code (Feature 5) will be used.
Feature 45
Area 4 – Option and Report Selections
Feature 45 is used to enable certain options that can be accessed or are visible to the user from the code pad of the
system. In addition, certain communicator reports are enabled. Each of these options can be enabled by area 4.
If the option selection feature for any area is left blank, that area will use Feature 16 for the option selection. Refer
to Feature 39 in this section for options table.
Feature 46
new
Area 4 – Entry / Exit Timers
Entry Time 1
Exit Time 1
Entry Time 2
Exit Time 2
Segments 1-6
30
60
30
60
Reserved
new
Reserved
new
Feature 46 sets the primary and secondary entry / exit times for area 4. If all segments in this feature are set to ‘0’, the
entry / exit time for this area will follow area 1 (Feature 17). Valid entries are 10-255 seconds
Feature 47
new
Area 5 – Account Code
Segments 1-6
10
10
10
10
Reserved
new
Reserved
new
Feature 47 contains the account code sent when area 5 is reported. If Feature 47 is left as default (all ‘10’s), then the