Patient Transport
42
Compella™ Bariatric Bed System Instructions for Use (178951 REV 6)
4.
Shorten the foot section as necessary (see “FlexAfoot™ Bed Length Adjustment” on page 35).
CAUTION:
Caution
—Before you transport the bed, remove the air supply unit from the footboard. Failure to do so
could cause equipment damage.
5.
Turn the air supply unit
Off
.
6.
Unplug the air supply unit from the AC power source.
NOTE:
The air surface will stay inflated during transport. To help with lateral transfers,
Max Inflate
the surface
before you disconnect it from the AC power; the surface will then stay firm.
7.
Unplug the power cord from the
air supply unit
.
8.
Use the magnets on the power cord to keep the power cord attached to the metal frame of the bed
and off the floor.
NOTE:
Make sure that the magnets do not interfere with the movement of the foot end section when the foot
section is lengthened or shortened.
9.
Disconnect the three color-coded air hoses from the patient left-hand side of the air supply unit.
10. Lift the unit and its hoses over the footboard, and set the unit and hoses on the foot or side section
of the bed.
11. At the head end of the bed, unplug the power cords for
both
the bed and the air supply unit. Use
the
blue
cord hooks at the head section to store cords during transport.
12. Put the brake/steer pedals in the
Steer
or
Neutral
position as necessary.
13. Transport the patient.
After the transport
, do as follows:
1.
When the bed is in the correct position, set the brake.
2.
Plug the power cords for both the bed
and
air supply unit into AC power.
3.
Replace the air supply unit:
a.
Move the unit from the foot or side section of the bed to the footboard.
b.
Connect the power cord and air hoses. Use the magnets on the power cord to keep the power
cord attached to the metal frame of the bed and off the floor. Make sure that the magnets will
not interfere with the movement of the foot end section when the foot section is lengthened or
shortened.
c.
Turn the unit
on
.
4.
After the transport, adjust the bed width and length as necessary for patient comfort and safety.
5.
Optional: To stow the push handles, pull them upward to unlock
them, and then swing them inward (toward the center of the bed)
into the stowed position.