![Hillrom Compella Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/hillrom/compella/compella_instructions-for-use-manual_2134337034.webp)
Information Indicators
20
Compella™ Bariatric Bed System Instructions for Use (178951 REV 6)
Off
—no lights will show on the indicator if the battery charge is too low to operate the bed.
NOTE:
There will be a
double
beep if the battery has gone to sleep and you press a bed articulation control.
This is the only time you will hear a
double
beep.
CAUTION:
Caution
—For transport, a fully-charged battery is preferred; however, if the battery charge is low,
before you unplug the bed, put the bed in the correct position before any transport, and connect the
bed to AC power as soon as possible.
If the Battery Indicator changes from Charged to Low consistently within four hours of being
disconnected from AC power, replace the battery.
While on battery power, the bed will operate as follows:
•
All of the bed functions will operate except for width adjustment. For manual width
adjustment, see “Manual Width Control” on page 34.
•
The integrated air surface will stay inflated, but it will not adjust pressures.
•
The Bed Exit and Scale functions will
not
operate.
Service Required
Hip Position Locator (earlier bed versions)
The hip position label on the intermediate siderails identifies the correct
position of the patient's hips while on the bed.
Correct placement of the patient increases the effectiveness of the SlideGuard®
Technology. This is designed to minimize patient migration to the foot end of
the bed when you raise the head section.
Head Pivot Locator
The head pivot locator label on the intermediate siderails identifies the
approximate pivot point of the head section.
Correct placement of the patient increases the effectiveness of the SlideGuard®
Technology. This is designed to minimize patient migration to the foot end of
the bed when you raise the head section.
The Service required indicator, on the caregiver control panel, flashes when the bed
detects a malfunction. Contact your facility-authorized maintenance person or
Hill-Rom Technical Support for assistance.
Bed Not Down
When the bed is not in its lowest position, the
Bed Not Down
indicator comes on.