High Valley Stoves by Stoll warrants its High Valley brand wood heaters to be free from defects in material or workmanship, under normal 
use and condi  ons of service, to the original purchaser, for a period of seven (7) years from the date of purchase subject to the following 
limita  ons:  Electrical Components

 

(blowers, switches, etc.) are warranted against mechanical and electrical failures, under normal use and 

condi  ons of service, to the original purchaser for a period of one (1) year.  High temperature ceramic glass is warranted to be free from 
defects in material, under normal use and condi  ons of service, to the original purchaser for a period of one (1) year.  Damage to glass 
caused by impact is considered abuse and is not covered under this warranty.  Cataly  c Combustors are warranted by the manufacturer 
for a period of 

fi

 ve (5) years.  The warranty is administered by the manufacturer of cataly  c combustors directly.  The original purchaser 

should register the purchase of any High Valley wood heater equipped with a cataly  c combustor with the manufacturer within 30 days of 
purchase using the warranty registra  on provided by the manufacturer of the cataly  c combustor.  Terms and exclusions of warranty on 
cataly  c combustors are established by the manufacturer of the cataly  c combustor and not by High Valley Stoves by Stoll.  The following 
items are not covered under warranty:  Gaskets, Paint, Damper, Damper Handles and Rod, Fireclay Bricks or castable lining, and all parts not 
permanently a   ached to the hea  ng unit.  Parts not permanently a   ached to the hea  ng unit are de

fi

 ned as any part removable with com-

mon hand tools.  If, a  er installa  on, assemblies and/or components covered under this warranty are found to be defec  ve in materials or 
workmanship during the warranty period, High Valley Stoves by Stoll will, at its op  on, repair or replace the covered components, subject 
to the limita  ons set forth in this warranty.

H

 V

 S

 L

 W

 C

 

This warranty is nontransferable and is extended exclusively for the ben-

e

fi

 t of the original purchaser, provided that the appliance purchase was made through an authorized High Valley dealer.  The wood heater 

should be used within 30 days of purchase by having a 

fi

 re started, the blower operated, and heat generated in the owner’s home to con

fi

 rm 

proper opera  on of all components.  The product must be installed, operated, and maintained in compliance with the instruc  ons set forth 
in the Owner’s Manual supplied with the product at all   mes.  Installa  on, setup, and start-up procedures are considered to be normal 
required ac  vi  es not associated with warranty service.  Issues such as adjustments or ven  ng should be included in setup of the product.  
Such procedures are not covered by warranty.  Any installa  on, construc  on, transporta  on, or other related costs or expenses arising from 
defec  ve part(s), repair, replacement etc., will not be covered by this warranty, nor will High Valley Stoves by Stoll assume responsibility 
for them.  Further, High Valley Stoves by Stoll will not be responsible for any incidental, indirect, or consequen  al damages.  This warranty 
cons  tutes the en  re warranty with respect to High Valley Stoves by Stoll and/or its products.  High Valley Stoves by Stoll makes no other 
warranty, expressed or implied, including any warranty of merchantability, or warranty of 

fi

 tness for a par  cular purpose.

E

 

 L

:

  

This warranty does not cover the following:  Damage caused by transporta  on and/or handling of 

the product;  damage due to incorrect installa  on not in accordance with the Installa  on Instruc  ons included with the product and any 
applicable na  onal, state, and local building and 

fi

 re codes, etc.;  [High Valley appliances must be installed by a quali

fi

 ed (preferably NFI 

cer  

fi

 ed) installer.  It is the installer’s responsibility to ensure that the product is installed and opera  ng correctly at the   me of installa  on.  

Chimney components and/or other non-High Valley accessories used in conjunc  on with the installa  on of this product are not covered 
under this warranty.]  Damage caused by improper use, which is not in accordance with the Instruc  ons for Use and Maintenance included 
with the product (over 

fi

 ring, use of corrosive fuel, etc.);  Damage caused by unauthorized modi

fi

 ca  on, use, or repair;  Damage caused by 

the use of non-High Valley spare parts or accessories;  Damage caused by lack of regular maintenance and cleaning by the owner as outlined 
in the Opera  ng Instruc  ons, or due to negligence or carelessness;  Damage caused by misuse, accident, neglect, or willful abuse of the 
product;  Damage caused by the use of any type of coal in any High Valley wood heater.  (The use of seasoned wood is required.);  Dam-
age due to accidental or uncontrollable environmental causes such as: intense cold, 

fi

 re, lightning, voltage overload or drop, inadequate 

ven  ng or ven  la  on, nega  ve air pressures cause by mechanical systems such as furnaces, fans, clothes dryers, etc., and Damage due to 
wiring or mechanical systems not in accordance with applicable na  onal, state, and local codes;  Damage caused by rust or corrosion due 
to condensa  on, dampness, humidity, or incorrect installa  on;  Calls for warranty service that are determined to be occasioned by lack of 
maintenance or factors not related to the High Valley appliance;  Normal wear and tear such as paint discolora  on, abrasion, worn gaskets, 
etc.;  Repair or replacement of wear-parts which are subject to normal wear and tear during the warranty period, or parts that may require 
replacement in connec  on with normal maintenance;  The installa  on of consumer replaceable items and installa  on of upgraded compo-
nents;  Noise resul  ng from the movement of motorized parts or minor expansion and contrac  on which is considered normal, not a defect.

T

 W

   V

  :

 

 The appliance has been over-

fi

 red.  Over-

fi

 ring can be iden  

fi

 ed by, but not limited to, warped 

fi

 rebox 

components, discolored cast iron, discolored, bubbled, or cracked painted 

fi

 nishes;  The appliance has been used to burn coal of any type;  

the appliance is subjected to prolonged periods of dampness or condensa  on;  There is any damage to the appliance or other components 
due to water or weather damage which is the result of, but not limited to, improper chimney or ven  ng installa  on.

L

   L

 

The exclusive remedy of the owner, and High Valley Stoves by Stoll's sole obliga  on under this warranty, and 

under any other warranty, express or implied, or in contract, tort or otherwise, shall be limited to repair or replacement as speci

fi

 ed above.  

High Valley Stoves by Stoll assumes no liability for incidental damages or damages of any kind which may arise from the use of its products.  
In no event will High Valley Stoves by Stoll be held liable for any incidental, indirect, or consequen  al damages caused by defects in its 
products.  The maximum amount recoverable under this warranty is limited to the purchase price of the product.  This Warranty provides 
speci

fi

 c legal rights and the consumer may have other rights that vary from state to state.  Some states do not allow exclusions or limita  on 

of incidental or consequen  al damages, so these limita  ons may not apply to you.  Except to the extent provided by law, High Valley Stoves 
by Stoll makes no express warran  es on its High Valley Stoves other than the warranty speci

fi

 ed herein.  The dura  on of any implied war-

ranty is limited to dura  on of the expressed warranty speci

fi

 ed above.

I  W

 S

   R

:

  

If, during the warranty period, a High Valley wood heater is proved to be defec  ve in material 

or workmanship, High Valley Stoves by Stoll will, at its own op  on, repair or replace the product as described below.  Any claim for war-
ranty service should be made to the dealer from whom this High Valley wood heater was purchased.  Confer with your dealer in advance 
to determine any addi  onal costs associated with a warranty service call.  Service charges and/or mileage are not covered under warranty.  
These charges vary from retailer to retailer.  Your authorized High Valley dealer will procure replacement parts and/or contact High Valley 
Stoves by Stoll to arrange for replacement should the appliance exhibit defects in material and workmanship which are beyond 

fi

 eld repair.  

Extraordinary repairs which are deemed to require replacement must be approved by High Valley Stoves by Stoll prior to said repair or 
replacement.  Any removal fees, transporta  on costs, reinstalla  on fees, construc  on costs, or any other related costs or expenses arising 
from replacement will not be covered by this warranty, nor will High Valley Stoves by Stoll assume responsibility for them.

W

 C

Содержание 2500

Страница 1: ...ou if you are required to obtain a permit before installa on Failure to follow these instrucƟons can result in property damage bodily injury or even death Owner s Manual Safety Installa on Opera on Maintenance Guidelines INSTALLER Leave this manual with the individual s responsible for opera ng this wood heater OPERATOR The Owner s Manual contains important safety opera ng and maintenance informa ...

Страница 2: ...al remains Salt water dri wood or other previously salt water saturated materials Unseasoned wood or Paper products cardboard plywood or par cleboard The prohibi on against burning these ma terials does not prohibit the use of fire starters made from paper cardboard saw dust wax and similar substances for the purpose of star ng a fire in an affected wood heater Burning these materials may result in...

Страница 3: ...rtant safety no ces and informa on may be repeated a number of mes The repe on is inten onal in an effort to reinforce safety instruc ons and to place them in context U S EPA E S T I P 2 G S I S P Page 4 I P P 5 C P P 6 C R G P 7 C C T D P 8 M 2500 F S C P 9 P I A P 10 F W H I P 11 F W H C C P 12 M 2500 M F I P 13 F I D S I P 14 P O A P 15 M 2500 F C P 15 O G P 16 17 T I P 18 C I T I P 19 C C R C P...

Страница 4: ...ese or other flammable liquids near a wood heater could cause a fire DO NOT BURN GARBAGE OR FLAMMABLE FLU IDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL Cord wood is the only fuel approved for use in this wood heater DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT A WOOD HEATER TO OR USE IN CONJUNCTION WITH ANY AIR DISTRI BUTION DUCTWORK UNLESS SPECIFICALLY APPROV...

Страница 5: ...number would depend on the size and layout of the home Installing your wood heater in an uninsulated basement is not recommended Much of the heat produced will be lost to the uninsulated walls of the basement Never cut holes or vents in a ceiling floor in an a empt to get warm air to rise to the rooms above You will be compromising a firebreak in your home and could should a fire ensue jeopardize ...

Страница 6: ...flue of the Model 2500 and can be an acceptable op on assuming that the masonry chimney provides adequate dra The cross sec onal area of an 8 round flue is 50 sq in Area πr2 or A π42 or A 3 14 X 16 where Pi 3 1416 The cross sec onal area of an 8 square masonry flue le is 64 sq in However masonry chimneys commonly have 8 x 12 96 sq in or even 12 x 12 144 sq in flue les which would be two 2X to thre...

Страница 7: ...ges roof flashings chimney caps etc must be installed exactly to the manufacturer s instructions Installation specification and clearances may vary from manufacturer to manufacturer and must be carefully adhered to according to the individual manufacturer s instructions If a new masonry chimney is to be constructed the use of a professional masonry contractor is strongly recommended Specialized kn...

Страница 8: ...s bles by a minimum of 6 inches 152mm of glass fiber insula on Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge 0 024 inch 0 61mm in thickness Supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold chimney sec on Fasteners used to secure chimney sec on shall not penetrate chimney flue liner Solid insulated list...

Страница 9: ...L 1618 Type 2 R 0 45 3 8 Asbestos Millboard or Equivalent with k 0 84 NOTE Clearances to combus ble materials may be reduced using shielding methods as described in the current edi on of NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appliances Any reduc on of clearances must be approved by the local Authority Having Jurisdic on M 2500 F S C M 2500 L M 2500 P Model 2500 Ove...

Страница 10: ...aler has the material handling equipment and experience to handle the weight of the Model 2500 Laying the Model 2500 on its back to install the legs is not recommended Leg breakage can occur as the assembled wood heater is being pped upright If you opt for this method remove the firebricks that line the firebox before pping the body Carefully li the body onto sturdy blocks or jacks capable of supp...

Страница 11: ...c on and allow final posi oning of the wood heater Remove the cardboard before ligh ng the first fire in the wood heater The wood heater should be centered on the chimney if possible to allow for the shortest and most direct connec on The wood heater does not necessarily need to be centered on the floor protec on as long as the minimum side protec on requirement 8 is met An asymmetrical installa o...

Страница 12: ...ctly under the chimney pipe if possible All Clearances to combus bles must be maintained Confirm that any ceiling support roof support fire stops insula on shields etc are installed cor rectly and match the brand of Type HT 2100 chim ney being used If the wood heater must be offset from the chim ney opening use 15 or 45 pipe elbows to make correc ons for the offset Crimped connector pipe ends must p...

Страница 13: ... nector installa on Ovalized connector pipe is available to fit through the damper opening and stainless steel damper adapter kits are available to seal the damper opening Save the damper plate and all parts If the insert is removed in the future the fireplace can be returned to working order Use only liner materials listed to appropriate UL standards and carefully follow all instruc ons provided ...

Страница 14: ...ound Remove the paper tape and adhere the gaske ng to the inside surface of the flanges facing the Insert body Start the four pressure screws into the tabs in the Surround Do not let the cap screw threads project through the tabs to prevent marring the Model 2500 Insert finish Check that the Insert is centered side to side in the fireplace open ing The front edge of the Insert top should be no mor...

Страница 15: ...rning wood heater Thermal shock could break the ceramic glass exacerbat ing the problem Hot steam could increase the risk of burns or scalding ALWAYS USE SAFE BURNING PRACTICES B S W F O This wood heater is designed and approved for the burn ing of cord wood fuel only Never burn any type of coal in this heater Burning any type of fuel other than cord wood in this wood heater is against all safety ...

Страница 16: ...seems uncontrollable consult your dealer A hand damper installed in the connector pipe will allow for manual control under high dra condi ons CAUTION Before ligh ng your cataly c equipped wood heater please read and or re read the safety informa on on Pages 2 4 15 and elsewhere throughout this man ual Ensure that the wood heater has been installed accord ing to the instruc ons given in this manual...

Страница 17: ...cial vacuums equipped with heat resistant filters and designed for ash clean up and removal are available through your dealer S O The amount and density of smoke com ing from the chimney is a visual indicator of how cleanly the wood heater is burning Develop a habit of checking the smoke opacity regularly and at various stages of combus on With experience a quick glance can confirm proper op era o...

Страница 18: ...rding to the guidelines on Page 16 17 You must develop and use good wood burning habits always open the Bypass Damper and Air Controls before opening the Loading Door and always open the Loading Door slowly to avoid pulling smoke from the firebox into the home A modern wood heater properly installed and connected to a good chimney which provides adequate dra should not leak smoke into the home Air...

Страница 19: ... on the probe is normal and does not affect the performance of the thermometer If you do choose to clean the probe stove glass cleaner made for dissolving creosote on ceramic glass should be used to gently wipe the probe C T The cataly c combustor technology used in the Model 2500 is similar in many ways to the cata ly c converters used on automobiles equipped with internal combus on engines Both u...

Страница 20: ...pt to remove the combustors from the housing at this stage Make a careful visual inspec on of the cataly c combustors Ash and soot residue on the combustors is normal and it can be gently removed with a so paint brush and or a vacuum cleaner with a so brush a achment With the loose ash removed con nue to inspect the cataly c combustor elements If only normal ash and soot accumula on are observed f...

Страница 21: ...s fallen out of the combustor F I Flame impingement occurs when open flame penetrates the cataly c combustors The Cataly c Combustor Housing is designed to minimize flame impingement by shielding the combustors from open flame S ll if the firebox is overloaded with wood and a roaring fire is established strong dra can suck flames into the combustor P S Aggressive cleaning with s ff brushes or hard ...

Страница 22: ...move the hinge pins and set them aside Lay the Loading Door face down on a well padded work surface Allow the Door Handle to hang over the edge of the table Remove the eight 8 screws and retainer clips Wearing gloves remove any remaining pieces of ceramic Place the replacement ceramic glass on a clean sec on of the pad ded work area Remove a short sec on of the paper backing that covers the gas ke...

Страница 23: ...turn the blower on and off automa cally based on tem perature and a Toggle Switch that allows the operator to choose between automa c and manual on off control P C The Power Cord is pre wired to exit the le side of the Convec on Blower Cover The Power Cord can be rerouted to exit on the right side of the Cover if a power outlet is more readily available on the right side of the installa on If you ar...

Страница 24: ...e 9 months for so woods and up to 24 months for hard woods to air dry thoroughly C Clean efficient combus on in your wood heater depends on burning well seasoned good quality fuel Buying seasoned wood in the burning season is ex pensive and o en disappoin ng The best advice is to get green wood in early spring and air dry it yourself If you don t cut your own wood find a reputable reliable wood sell...

Страница 25: ...18 the Standard for Wall Protectors Floor Protectors and Hearth Extensions was adopted as a standard in 2011 UL 1618 categorizes floor and wall protectors as Type 1 or Type 2 protec on A seemingly minor change in UL 1618 calls for the actual thermal proper es of floor protec on to be speci fied in R value in place of k value In fact that change makes it one step simpler to calculate thermal protec...

Страница 26: ... of corrosive fuel etc Damage caused by unauthorized modifica on use or repair Damage caused by the use of non High Valley spare parts or accessories Damage caused by lack of regular maintenance and cleaning by the owner as outlined in the Opera ng Instruc ons or due to negligence or carelessness Damage caused by misuse accident neglect or willful abuse of the product Damage caused by the use of a...

Страница 27: ...csimile of the Safety Label which is a ached to the back of your Model 2500 is provided for the convenience of the owner the Authority Having Jurisdic on or any other inspector who wishes to verify the contents of the label In some installa ons the label is not easily accessible Please record the serial number off the original label for your records ...

Страница 28: ...H V S S 185 Highway 201 Abbeville SC 29620 www highvalleystoves com HL2550 Rev 05 2015 NOTES ...

Отзывы: