04.24.2015
Mutant Hot Glue DIY assembly manual v1.05
PG20
HEXINVERTER ÉLECTRONIQUE, 2015
STEP 2:
Deactivate the compressor’s gain reduction, with the following settings…
STEP 3:
While viewing and comparing the COMP output signal to the input signal, adjust the
SYMMETRY ADJUST
control for best vertical symmetry. See the images below for how to do this…
The upper and lower peaks of the output waveform (blue) are not symmetrical. You can tell
by inspecting the vertical distance between the yellow and blue waveforms.
At first glance, this might seem okay – but pay close attention! – the output waveform (blue) is
above and below
the input
waveform! This is not correct, as we will see in the following correct example.
GAIN = 0dB
BLEND = WET (100%)
THRESHOLD = +26dBu
RATIO = MAXIMUM
POOR SYMMETRY
POOR SYMMETRY