Operating the device
44
To deactivate automatic model light reduction (“Autored”), proceed as
follows:
Turn the rotary switch counter-clockwise until two dashes appear on
the display.
Checking the function of the model lamp
If the model light illuminates, one of the two LED displays lights up above
the FULL and PROP buttons. If the two LED displays above the FULL and
PROP buttons do not light up, proceed as follows:
Press the FULL button.
The LED display above it lights up green.
If the model light does not light up despite an illuminated LED display
above the FULL or PROP buttons, check the illuminant and the fuse.
Setting the flash energy
Depending on the device, the flash energy is set in stages using a rotary
switch over an adjusting range of 9 f-stops from 2 (lowest flash energy) to
10 (highest flash energy) and 8 f-stops from 3 (lowest flash energy) to 10
(highest flash energy). To set the flash energy, proceed as follows:
To increase the flash energy in increments of 0.1 f-stops, turn the rotary
switch clockwise.
To decrease the flash energy in increments of 0.1 f-stops, turn the
rotary switch counter-clockwise.
When the flash energy is changed, the LED display above the TEST button
goes out until the selected flash energy is ready.
When the flash energy is reduced, the previously accumulated energy
is released internally using the integrated APD function.