Operating the device
43
Activating and deactivating the model light
“Full” mode
To activate the model light in “Full” mode, proceed as follows:
Press the FULL button.
The LED display above the FULL button lights up green. The model light
illuminates at maximum brightness, irrespective of the set flash energy.
To deactivate the model light in “Full” mode, proceed as follows:
Press the FULL button again.
The LED display above the FULL button goes out.
“Prop” mode
To activate the model light in “Prop” mode, proceed as follows:
Press the PROP button.
The LED display above the PROP button lights up green. The brightness of
the model light is proportional to the set flash energy.
To deactivate the model light in “Prop” mode, proceed as follows:
Press the PROP button.
The LED display above the PROP button goes out.
Activating and deactivating automatic model light reduction (“Autored”)
The device is equipped with an automatic model light reduction
(“Autored”). After a preset time of 35 minutes, the brightness is dimmed to
half (level 9) in “Full” mode. In “Prop” mode, the brightness is reduced to
half when the flash energy is set in a range from 9.1 to 10. To activate
automatic model light reduction, proceed as follows:
Press the rotary switch twice in succession.
The preselected time for automatic model light reduction (“Autored”) is
shown on the display for approx. 3 seconds.
In one-minute increments, set the time up to a maximum of 90 minutes
using the rotary switch.