![Henny Penny Velocity OXE-100 Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/henny-penny/velocity-oxe-100/velocity-oxe-100_operation-manuals_2124401067.webp)
55
Menu Item
Function
•
- - No signal present
•
DTF - Discard Tank Full
•
FULL - Discard tank is full and cannot dispose to it
•
OK - Discard tank not full, okay to dispose
Pressure Inputs
n/a
Manifold Pressure
Displays pump pressure reading if optional transducer is installed in plumbing manifold
as:
•
* - On
•
- - Off
otherwise displays NO SENSOR.
Fryer Outputs
•
* - On
•
- - Off
•
Pri - Primary Contactor
•
Ht - Heat (regulating) Contactor
•
Pr - Pressure Solenoid (n/a)
•
BSV - Bulk Supply Valve (optional)
Drain Valve (Con-
trol) Status
•
Par - Partially open
•
Stp - Forced Stop
•
Opn - Fully Open
•
Cls - Fully Closed
•
► - The current state of the drain valve
•
At - indicates the drain valve position
–
0 - Fully Closed
–
20+ - Fully Open
Selector Valve
(Bulk Oil Fryers
Only)
Displays in the lower right with the current port position as:
•
No Selector Valve - unit is not equipped with a Bulk Oil System
•
E=001 - Encoder Position
Displays in the lower left with the activity of the valve as:
•
STPD - Stopped
•
FWD - Forward
•
REV - Reverse
Содержание Velocity OXE-100
Страница 2: ......
Страница 7: ...Contents v ...
Страница 9: ...Contents vii Figure 10 27 Screen 6 97 Figure 10 28 Screen 7 98 ...
Страница 10: ...Contents viii ...
Страница 20: ...Unpacking and Installation 8 ...
Страница 26: ...Initial Startup 14 ...
Страница 38: ...Oil Maintenance 26 ...
Страница 44: ...Cooking 32 ...
Страница 60: ...Maintenance 48 ...
Страница 115: ...Annual Inspection Checklist Form 103 ...
Страница 116: ...Annual Inspection Checklist Form 104 ...
Страница 117: ...blank page ...